background image

¡

Installation should always be carried out by specialist. The customers should not install 
the air-conditioner by themselves. Otherwise, it may cause damage or injury.

Safety tips

Set the suitable temperature, especially there are old people, children and patients  in the 
room. Generally, keep the temperature difference for 5¡ between the inside and outside. 

In case that the unit occurs closing down due to the severe interference from outer 
environments such as mobile phone, please cut off  the plug and  plug  in to restart the 
air conditioner after several seconds .

Never expose animals or plants to direct air flow, and adjust the air flow to avoid air
blowing directly at people. 

¡

¡

Notices 

Make sure that air outlet and inlet are not blocked. 

Make sure that the earth wire is connected safely and reliably.
Make sure the filter net is properly fixed.

Please clean the filter before starting the air-conditioner referring to page to 6
¡Cleaning¡for how to operate. 

Checking before operation

To prevent injury and property damage, Please pay attention to these following before 
operating the air conditioner.

Working condition 

When outdoor temperature is more than 43¡ or lower than 18 ¡(dry temperature ),
the air conditioner can not operate Cooling mode.

When outdoor temperature is more than 24¡ or lower than -7¡(dry temperature ),
the air conditioner can not operate Heating mode.

-4-

Klimaire Products Inc.   All rights Reserved
Operation Manual - Ductless Systems   KSWX012-H113, KSWX018-H213, KSWX024-H213, 

Summary of Contents for CFWX019-C213

Page 1: ......

Page 2: ...tices 4 Care and Maintenance 6 Troubleshooting 6 Installation Guide 8 Technical Specifications 9 Remote controller operation 3 Manual operation 3 Checking before operation 4 Cleaning 6 Maintenance 6 G...

Page 3: ...er with wet hands It will cause electric shock Don t install air conditioner in a place where there is flammable gas or liquid Don t put a finger a rod or other object into the air outlet or inlet Don...

Page 4: ...ner Air filter Drain pipe Pipe and Drain pipe Cut off valve Outlet cover 11 12 Outdoor Unit Fig 1 Pipe protection ring Note All picture in this manual are for explanation purpose only They may be slig...

Page 5: ...anually Adjusting h Remote controller operation See air conditioner remote controller instruction 2 Adjusting vertical air flow direction up down Refer to air conditioner remote controller instruction...

Page 6: ...avoid air blowing directly at people Notices Make sure that air outlet and inlet are not blocked Make sure that the earth wire is connected safely and reliably Make sure the filter net is properly fix...

Page 7: ...er regularly Close the windows and doors otherwise cooling or heating capacity will be weakened the Don t install the indoor unit under sunshine directly Don t block air inlet or air outlet otherwise...

Page 8: ...ner polishing powder benzene and other volatile chemicals Don t use water above 45 to wash the panel or it could cause deformation or depigment 1 Raise up the front panel of indoor unit until it sudde...

Page 9: ...and it looks like the fog This generate due to moisture in defrosting process Low noise can be heard during operation A low hissing sound is caused by the refrigerant flowing A low squeak sound is cau...

Page 10: ...mum current If your air conditioner is not fitted with a supply cord and a plug a If your air conditioner is permanently connected to the fixed wiring and have a leakage current that may exceed 10 mA...

Page 11: ...Technical Specifications 9 Klimaire Products Inc All rights Reserved Operation Manual Ductless Systems KSWX012 H113 KSWX018 H213 KSWX024 H213 KFWX019 C213...

Page 12: ...7909 N W 54th Street Miami FL 33166 USA Phone 1 305 593 8358 Fax 1 305 593 8212 e mail sales klimaire com www klimaire com...

Reviews: