10
ENGLISH
OPERATING INSTRUCTIONS
AC/DC VOLTAGE (LESS THAN 600V)
1. Insert RED test lead into VΩ jack
5
, and BLACK test lead into
COM jack
4
, and rotate function selector switch
2
the V
setting.
NOTE:
The meter defaults to AC measurement. Press the "SEL"
button
10
to toggle between AC and DC modes. The AC or DC
icon on the LCD indicates which mode is selected.
2. Apply test leads to the circuit to be tested to measure voltage.
The meter will auto-range to display the measurement in the
most appropriate range.
NOTE:
If "
–
" appears on the LCD, the test leads are being applied
to the circuit in reverse polarity. Swap the position of the leads to
correct this.
NOTE:
When in a voltage setting and the test leads are open,
readings of order mV may appear on the display. This is noise and
is normal. By touching the test leads together to close the circuit
the meter will measure zero volts.
Red lead
Black lead
www.
GlobalTestSupply
.com
Find Quality Products Online at: