ELECTRICAL SUPPLY
Before installing the oven have a qualified
electrician verify that your home is provided with
adequate electrical service and that the addition
of the oven will not overload the circuit on which it
is to be installed. A separate three-wire single
phase, 240 V, 50 Hz circuit is required.
WARNING!
ELECTRICAL SHOCK HAZARD
The electrical power to the oven circuit must be
shut off while line connections are being made.
Do not use an extension cord with this
appliance.
Electrical ground is required on this appliance.
The free end of the yellow/green wire (the
ground wire) must be connected to a suitable
ground. This wire must remain grounded to the
oven.
A qualified electrician must install the appliance.
The oven must be earthed in accordance with
the current Australian Standard.
The oven must be connected to the mains
through a multipole circuit breaker with a
contact-to-contact gap of a least 3 mm, marking
sure that the earth wire is not disconnected.
Failure to follow these instructions could result in
serious injury or death.
Wiring Requirements
Before making connections make sure the power
is off and read and observe the following:
A separate three-wire, single phase, 240 V,
50 Hz. circuit is required for the oven.
The oven must be connected with COPPER
WIRE ONLY.
The oven must be installed to conform with
the current Australian Standard.
Wire size (COPPER WIRE ONLY) and
connections must be suitable for the rating of
the appliance per the current Australian
Standard.
Connecting The Oven To The Mains
For connecting use a flexible rubber cable of the
H05BBF type (3x1.5 mm
2
min for single oven,
3x4 mm
2
min for double oven) remembering to
make it long enough to allow the oven to be
removed from its housing unit when maintenance
work is required. To connect the cable to the
oven proceed as follows (see fig. 11):
1. Remove the lid (1) by unfastening the three
screws (2). Unfasten the two screws (3) for
the cable holder and feed the cable through
the opening immediately below the cover.
2. Remove about 12 cm of the outside insulation
from the cable and shorten the two active
wires (live and neutral) to 6 cm, leaving long
the one to be connected to the main earth
terminal on the terminal block; remove about
1 cm of the main insulation from the three
wires and connect them correctly to the
terminal block, remembering to respect the
polarities.
3. Tighten the two screws (3) of the cable holder
and put the lid (1) back on with the three
screws (2).