Problem
Possible cause
Remedial action
Start/Pause
indicator light
d
indicator
lights.
The display
shows
0:00
.
l for 30
min. and then turn on again.
doesn’t
illuminate.
Anti
Crease/en
Fault in program sequence or
malfunction.
Turn off dryer, leave to coo
Restart program.
Moisture sensor dirty.
Clean moisture sensor, then
dryer off and on again.
turn
Exhaust air duct is blocked or
too long.
Clean exhaust air duct or sh
it below maximum length
orten
allowed.
Turn dryer off and on again.
Filter dirty.
Clean filter and then turn dryer off
and on again
Laundry was too wet.
Spin laundry at higher speed in
the washing machine. Turn dryer
off and on again
Unsuitable program selected.
gram and then
Select suitable pro
turn dryer off and on again
Maximum drying time
exceeded.
Clean filter and exhaust air duct.
Spin laundry at a higher speed in
your washer (t
water).
o remove more
Motor limit temperature was
exceeded.
Turn off dryer, leave to cool for 30
min. and then turn dryer off and
on again.
Degree of
drying has not
been reached
or the drying
time is too
y may
.
s not set
correctly.
for degree of
dryness.
long.
Displa
indicate
E:03
Degree of drynes
Change settings
5.5 NTC
ratings
5.5.1 NTC R2 ratings (@ heater)
5.5.2 NTC R3 ratings (@ lint screen)
•
@ 25ºC (77ºF) = 10 k
Ω
•
@ 40ºC (104ºF) = 5.3 k
Ω
•
@ 50ºC (122ºF) = 3.6 k
Ω
•
@ 60ºC (140ºF) = 2.4 k
Ω
Hi-limit
NTC
Heater
NTC
•
@ 25ºC (77ºF) = 25 k
Ω
•
@ 50ºC (122ºF) = 7.2 k
Ω
•
@ 80ºC (176ºF) = 2.4 k
Ω
•
@ 100ºC (212ºF) = 1.3 k
Ω
702_58300000121945_ara_en_a