5.1.9 Fan 

Remove front panel and bearing shield (5.1.6).  Remove fan front 
cover to access fan.  Fan is located on front of motor shaft, which has 
left-handed thread.  To remove fan from motor shaft, use a 1” wrench 
and rotate fan (clockwise) from left to right. 

 

 
When removing fan, hold motor shaft, not motor rotor fins, to avoid 
damaging fins.  

5.1.10  Anti Crease/end light 

If the A

nti Crease/end

 light is on while the display is off, an internal 

switch (S3) on the control board has been damaged and the entire 
control module has to be replaced. 

 

5.1.11  Serial # (E-Nr) label 

The serial # label is located below the door and shows the model (E-
Nr) and serial # of the dryer. 

 

Turn cw to loosen (left-handed thread)

 

702_58300000135249_ara_en_a 

Page 12 of 21 

Summary of Contents for KED2000

Page 1: ...t vents 3 2 3 Feet leveling legs 3 3 OPERATION 4 3 1 Controls 4 4 COMPONENTS 5 4 1 Dryer Components 5 5 REPAIR 9 5 1 Disassembly Reassembly 9 5 2 Diagnosing troubleshooting 13 5 3 Dryer noise 14 5 4 C...

Page 2: ...ning service c Carefully follow all servicing instructions Verify the instructions if there are any that you don t fully understand c Read and heed all Cautions and Warnings on the appliance and those...

Page 3: ...p connector notch with the vent tab 2 2 2 Installing vent ducts For best drying use shortest possible duct length and fewest of elbows Use the table below when selecting ducting 90 Turns Maximum Lengt...

Page 4: ...er LED Reminder only to clean the lint filter There is no sensor showing lint levels LED indicator lights Program cycle selector knob Additional options buttons Menu chooses options and Select changes...

Page 5: ...and a manually resettable hi limit temperature protector NTC temperature sensor Heater terminals Front bearing shield Control module Push red button to reset Hi limit protector Hi limit protector Fan...

Page 6: ...ally reset by pushing the left plunger in viewing rear of dryer the dryer will not run if the switch hasn t been reset 4 1 5 Air exhaust duct Air exhaust duct connects to the fan and allows exhausting...

Page 7: ...oor pin Door pin engages the door switch notifying the dryer the door is closed for drying If the door pin is damaged the entire door assembly must be replaced A T 20 screw on the door pin cover can b...

Page 8: ...lacing the seal make sure all old adhesive is removed and no new adhesive gets onto the drum Any excess adhesive or residue may cause squeaking 4 1 12 Drum with bands Drums have two steel bands around...

Page 9: ...d knob Don t cut cable mounts cut cable ties holding cables to mounts When reassembling use new cable ties 5 1 3 Top panel worktop Remove two T 20 Torx screws with washers from rear of dryer slide pan...

Page 10: ...once drum cover has been removed 4 Drum sleeve bearing can be removed from drum cover by removing four T 20 Torx screws Drum sleeve bearing Outer bearing race Drum axle 5 1 6 Heater Drum Drum cover Be...

Page 11: ...cradle 5 1 8 Front panel and bearing shield 1 Remove fascia panel 5 1 1 If necessary for access remove top panel 5 1 3 2 Remove door and door hinge 3 Remove two T 20 Torx screws at top and bottom of...

Page 12: ...g fan hold motor shaft not motor rotor fins to avoid damaging fins 5 1 10 Anti Crease end light If the Anti Crease end light is on while the display is off an internal switch S3 on the control board h...

Page 13: ...utout tripped Clean lint screen and clean lint and other debris from front shield then replace hi limit Also check exhaust duct length of elbows Heating element failed Check voltages to and resistance...

Page 14: ...f fresh air and then turn dryer off and on again No program selected Select program Light bulb defective light bulb burned out Change light bulb No power supply Guarantee power supply Drum light doesn...

Page 15: ...Turn dryer off and on again Unsuitable program selected gram and then Select suitable pro turn dryer off and on again Maximum drying time exceeded Clean filter and exhaust air duct Spin laundry at a...

Page 16: ...diately stop dryer by rota Off position then open do 2 Remove and clean filter 3 Replace filter and let dryer cool down 4 Close door then rotate cycle selector knob to desired cycle and press If the w...

Page 17: ...tester for example Meratester 5 f can be necessary inspection process with 180 twisted power connector ones again do Inspection Process must be done with cold Appliance to prevent that Heater Element...

Page 18: ...or LCD segments are illuminating n All LEDs and s CD segments are activated All LEDs and or LCD segments are illuminating successive in 0 5 sec steps All LEDs and or L successive in 0 5 sec steps Sequ...

Page 19: ...n Off blank 10 1 s On blank Off 11 1 s On Off blank 12 1 s On blank Off 13 1 s On Off blank 14 1 s Off On blank 15 10 s only drying LED ON Counts from 0 30 to 0 20 descending Off 16 10 s Off only Damp...

Page 20: ...if so ontrol is OK and shouldn t be replaced If heater and motor turn on together during Step 2 relay has failed and control must be changed ay is on ule relay diagnostics on the control If heat g e...

Page 21: ...lbows Rigid Duct Flexible Duct 0 20 m 14 m 1 17 m 11 m 2 14 5 m 9 m 3 12 m 7 m 4 9 m 5 m 7 1 7 Air flow volume flow rate vs exhaust duct length 100 110 120 130 140 150 160 170 180 190 200 210 220 230...

Reviews: