INSTALLATION INSTRUCTIONS
The installation is the exclusive responsibility of specialists.
The user of this appliance is held to respect the legislation and the standards enforced in his home country.
How to stick the gasket:
Fitting - installing:
•
The dimensions are:
Cut size (mm)
Glass size (mm)
Ref.
Width
Depth
Width
Depth
Thickness
w
d
W
D
KCITC6010
560
490
590
520
4
•
Ensure that there is a distance of 50 mm between the hob and the wall or sides.
•
The hobs are classified as “Y” class for heat protection. Ideally the hob should be installed with plenty of space on
either side. There may be a wall at the rear and tall units or a wall at one side. On the other side, however, no
unit or device can be higher than the hob.
•
The piece of furniture or the support in which the hob is to be fitted, as well as
the edges of furniture, the laminate coatings and the glue used to fix them, must
be able to resist temperatures of up to 100 °C.
•
The mural rods of edge
s
must be heat-resisting.
•
Do not install the hob to the top of a non- ventilated oven or a dishwasher.
•
To ensure good air circulation of the electronic device, maintain a space of 20
mm under the bottom of the hob casing.
•
If a drawer is placed under the work, avoid putting flammable objects in this
drawer
(for example: sprays) or non-heat-resistant objects.
•
Materials which are often used make worktops expand on contact with water.
To protect the cut-out edge, apply a coat of varnish or special sealant. Particular
care must be given when applying the adhesive joint supplied with the hob to
prevent any leakage into the supporting furniture. This gasket guaranties a
correct seal when used in conjunction with smooth work top surfaces.
•
The safety gap between the hob and the
range
hood placed above must comply
with the recommendations of the hood manufacturer. In case of no instructions,
a minimum distance as specified by AS/NZS 5601 should apply.
•
The connecting cable cannot be subjected to mechanical constraint (e.g. a drawer) after construction.
•
The cooktop underside temperature exceeds 95 c, an underbench board is required to be installed to prevent
underbench access.
•
WARNING: Use only hob guards designed by the manufacturer of the cooking appliance or indicated by the
manufacturer of the appliance in the instructions for use as suitable or hob guards incorporated in the appliance.
The use of inappropriate guards can cause accidents.
Stick the gasket (2) two millimetres from the
external edge of the glass, after removing the
protection sheet (3).