22
CLEARANCES
Installation clearances and protection of combustible surfaces shall comply with NZS 5261
Appendix F1.2 or section S 12 of AG 601.
Installation shall comply with the Dimension in fig. 17 bearing in mind:
Overhead Clearances
In no case shall clearances between the highest part of the cooker be less than 600mm or for
an overhead exhaust fan 750mm. All other downward facing combustible surfaces less than
600mm above the cooker surface shall be protected for the full width of the cooking surface
in accordance with the standards noted above. In no case shall the clearance be less than
450mm.
Side Clearances
Where the dimensions from the periphery of the nearest burner to any vertical combustible
surface is less than 200mm the surface shall be protected in accordance with the standards
to a height of not less than 150mm above the cooking surface for the full width or depth of the
cooking surface.
Protection of combustible surfaces
The standards above specify that where required protection shall ensure that the surface
temperature of the combustible surface does not exceed 50°C above room temperature.
Fig. 17
650 mm
450 mm
500 mm
Summary of Contents for FEG 600 X
Page 1: ...DUAL FUEL COOKER Instructions for Use and Warranty Details Model FEG 600 X THE WORLD S BEST...
Page 29: ......
Page 30: ......