30
15/ INDICATIONS FOR THE TESTING LABORATORIES
ENERGY EFFICIENCY TESTS ACCORDING TO AS/NZS 2007 PROGRAMME :
— Washing capacity - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
13 standard place settings
— Arrangement of the items - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Figs. A-B-C; IIE
EC
C load (next page)
— Loading as per the indications on next page, without side shelves.
— Setting for upper basket - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Low position
— Dosage of detergent - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
5 + 26.25 g of detergent
— Setting for rinsing product distributor - - - - - - - - - - - - - - - - - -
2
— The water softener must be set to 0-10°F
instructions in the paragraph on “Adjusting the water softener”.
— Door ajar 100 mm upon completion of dry test.
For more information on the comparison tests in accordance with AS/NZS 2007, please contact the
manufacturer of the machine before commencing testing.
N
NB
B:: When conducting tests using a multi-function tablet:
- Check that the water softener is correctly set for the water hardness (Chapter 5 / DETERGENT
PRODUCTS AND ADJUSTING THE WATER SOFTENER • FOR MULTI-FUNCTION PRODUCTS)
- Pull out the detergent distribution drawer and place the tablet in the interior compartment.
•
Measuring the noise level in accordance with Standard EN60704-2-3:
— Align the plinth on the housing unit with the door panel.
Normal Eco