A(mm)
B(mm) C(mm)
D(mm)
E(mm)
F(mm)
G(mm)
H(mm)
273
505
50min
50 min
50 min
50 min
48
52
Under
all
circumstances, make sure the ceramic
cooktop
is well ventilated and
the air inlet and outlet are not blocked. Ensure the ceramic
cooktop
is
positioned correctly as shown below.
The safety gap between the
cooktop
and the rangehood placed above must
comply with the recommendations of the rangehood manufacturer. In case of
no instructions, a minimum distance of 650mm (or other minimum distance as
may be specified by AS/NZS 5601 and interpreted by a certified installer)
should apply.
Note: The safety distance between the hotplate and the cupboard above
the hotplate should be at least 760mm.
A(mm)
B(mm)
C(mm)
D
E
760
min
50 min
30 min
Air intake
Air exit 10 mm
Installation
18
NOTE: Before making preparations for or commencing installation, the
installer should refer to the current online version of the User Manual,
which is available on the Kleenmaid website (see back cover for details).
Benchtop Prep
a
ration
Cut out the work surface according to the sizes shown in the drawing. For the
purpose of installation and use, a minimum of 5
0mm
space shall be preserved
around the hole.
Be sure the thickness of the work surface is at least 30mm. Please select heat-
resistant work surface material to avoid
deformation caused by the heat
radiation from the hotplate. As shown below:
Note: The seal
,
as
shown in this
illustration
,
is a
factory
-
fitted
foam strip.