Klavis Logica XT User Manual Download Page 11

 
Klavis

 

 

Logica 

XT 

user manual V1.0 

Page 

11

 of 

11

 

 

Specifications 

Mechanical 

Dimensions 

mm 

inches 

Eurorack compliance 

Height 

128.40 

5.06 

3HE 

Width 

25.00 

0.98 

5HP 

Depth behind panel (with supply cable inserted) 

25.00 

0.98 

 

 

Supply 

The supply socket is protected against reverse insertion. 

Supply rail 

Current draw 

+12V 

0 mA 

-12V 

1 mA 

+5V 

17 mA 

 

Input/output 

All inputs and outputs can withstand signals between -12V and +12V without harm. 

Jack 

Effective voltage range received or generated 

CV control input 

-5V to +5V 

All outputs 

0 or 5V (logic levels) 

Input low to high change 

3.5V or higher 

Input high to low change 

2.8V or lower (incl. negative) 

 

Signals 

Parameter 

Values 

Frequency range 

DC to beyond audio 

 

Packing list 

The box contains: 

 

Logica XT module 

 

2x M3 black mounting  washers 

 

Eurorack-compliant 16-pin supply cable 

 

Quick setup 

n

otice 

 

Klavis

 products, including PCB and metalwork, are designed and manufactured in Europe. 

 

Summary of Contents for Logica XT

Page 1: ...D S H 1 High Off Gt Tr S R C Features at a glance 14 modes of operation o 6 basic logic functions o 2 forced states o 6 advanced logic functions The Gater adds up multiple gate signals while maintaini...

Page 2: ...ing up the current draw of all modules mA separately for each of 5V 12V and 12V rails If any of these 3 sums exceeds the available current of your supply for that voltage do not connect the module to...

Page 3: ...With simple logic functions these all work in the same way Any signal can be brought to any jack Normalization With simple logic unused jacks automatically get the necessary default value so that it i...

Page 4: ...active column Manual input button This button acts as a fourth input The default status of the button depends on the logic function selected Where it makes sense this default status can be changed by...

Page 5: ...ccepted and within that half only levels high enough will produce a logic one on the output So changing the amplitude or the voltage offset of the saw will change the width of the resulting pulse saw...

Page 6: ...ate sounds much different from cascading multiple 2 input Xor the div 2 out can even provide melodies out of subtly detuned static pitches Here is the detail of the Xor Xnor function Input jacks Out j...

Page 7: ...ines all inputs as an Or function does but also retriggers the output every time a new gate starts while one or more are already active All inputs work the same the button brings a 4th gate signal The...

Page 8: ...input 1 Signals may overlap only their rising edge is considered for proper validation The manual button inverts the current state of the output Coin This function offers 3 heads or tails random gener...

Page 9: ...l be delayed Turning the pot within its first half the LED column indicates the delay as follows LED off 1 input is copied to out on the next clock then up one LED at a time corresponding to 2 3 4 6 8...

Page 10: ...ne Below lowest Off Off On Input jacks are disabled Button inverts Summary Advanced logic White LED Function Out jack Details Top On On Input jacks are disabled Button inverts 1 2 Gater On if at least...

Page 11: ...and outputs can withstand signals between 12V and 12V without harm Jack Effective voltage range received or generated CV control input 5V to 5V All outputs 0 or 5V logic levels Input low to high chan...