45
EN
Information according to regulation (EU) No. 206/2012
Description
Symbol
Value Unit
Rated capacity for cooling
P
rated
for cooling
3,5
kW
Rated capacity for heating
P
rated
for heating -
kW
Rated power input for cooling
P
EER
1,4
kW
Rated power input for heating
P
COP
-
kW
Rated Energy efficiency ratio
EERd
2,6
-
Rated Coefficient of performance
COPd
-
-
Power consumption in thermostat-off mode
P
TO
-
W
Power consumption in standby mode
P
SB
0,8
W
Electricity consumption of single/double
duct appliances (indicate for cooling and
heating separately)
SD: Q
SD
1,4
SD: kWh/h
Sound power level
L
WA
65
dB(A)
Global warming potential
GWP
3
kg CO
2
eq.