32
EN
Heating function
Note
: This function is not available for models that have only one cooling unit.
• Press and hold the Mode button until the heating icon appears on the screen.
• Press the TEMP+/TEMP buttons to select the desired room temperature (16-31 °C).
• Press the SPEED button to select the fan speed.
Automatic switch-on time (timer)
• When the unit is turned off, press the TIMER button and select the desired power-on
time.
• Preset ON Time“ is displayed on the screen.
•
The on time can be selected at will (00:00 - 24:00).
Automatic switch-off time (timer)
• When the unit is turned on, press the TIMER button and select the desired off time.
• Preset OFF Time“ is displayed on the screen.
•
The off time can be selected at any time (00:00 - 24:00).
Safety function of the inner water tank
The internal water tank has a safety function that controls the water level. When the
water level reaches a certain level, the water level indicator light illuminates to indicate
that the water tank is full (If the water pump motor is damaged and the water tank is full,
remove the rubber plug on the bottom of the unit to drain all water).
Note
: If you plan not to use this unit for an extended period of time, remove the
rubber plug from the drain hole at the bottom of the unit and drain all water to the
outside.