27
EN
Assembly instructions
The ceramic hob is designed for operation with a
three-phase household power supply (3*400V/220V
50Hz). The nominal voltage of the heating elements of
the ceramic hob is 230 V. Adaptation of the ceramic
hob to operation with single-phase current is possible
by means of appropriate bridging in the terminal
box according to the connection diagram below. The
connection diagram is also located on the cover of
the terminal box. Remember that the connection cable
should match the connection type and the rated power
of the ceramic hob. The connection cable must be
secured in a strain relief clamp.
Wiring diagram
Caution! The voltage of the heating
elements is 230 V. Caution! The earth
cable must be connected to the
PE
terminal when making a connection.
Recommended
connection
cable
1
For a single-phase connection
230 V, connect terminals 1-2 and
connect the earth cable to
.
H05VV-F
3G2.5
2
For a two-phase connection
400 V / 230 V, connect the earth
cable to
.
H05VV-F
4G2.5
L1=R, L2=S, L3=T, N= neutral cable connection, PE=earth connection
Cooker surface
Worktop
Tension clamp
Screw
Summary of Contents for 10034603
Page 2: ......
Page 7: ...7 DE ...
Page 14: ...14 DE ÜBERSICHT 4 ZONEN KOCHFELD Bedienfeld 4 Zonen ...
Page 25: ...25 EN ...
Page 32: ...32 EN OVERVIEW 4 ZONE HOB Control panel 4 zones ...
Page 43: ...43 ES ...
Page 50: ...50 ES VISIÓN GENERAL DE LA PLACA DE COCCIÓN DE 4 ZONAS Panel de control 4 zonas ...
Page 61: ...61 FR ...
Page 68: ...68 FR APERÇU DE LA PLAQUE DE CUISSON 4 ZONES Panneau de contrôle 4 zones ...
Page 79: ...79 IT ...
Page 86: ...86 IT PANORAMICA PIANO COTTURA A 4 ZONE Pannello di controllo 4 zone ...
Page 93: ......
Page 94: ......
Page 95: ......
Page 96: ......