37
Notes
• All wires of indoor unit and outdoor unit should be connected by a professional. for a new one. Avoid
extending the wire by yourself.
• For the air conditioner without plug, an circuit break must be installed in the line.
• The air switch should be all-pole parting and the contact parting distance should be more than 3mm.
3. Remove the wire clip; connect the power
connection wire to the wiring terminal
according to the color; tighten the screw and
then fix the power connection wire with wire
clip.
4. Put wiring cover back and then tighten the
screw.
5. Close the panel.
N(1) 2
blue black
yellow-
green
Outdoor unit connection
3
brown
Step 8: bind up pipe
1. Bind up the connection pipe, power cord and drain hose with the band.
indoor unit
gas
pipe
indoor and
outdoor power cord
liquid pipe
drain hose