32
Only connect the appliance to the power
supply once it is properly installed.
7.2 Using the extractor hood as
an exhaust air hood (with air
extracted to outdoors)
If the extractor hood has been
fi
tted at
the factory with a carbon
fi
lter, this must
be removed. It is only practicable to use
this when operating your hood in circula-
tion mode.
7.3 Converting the extractor
hood to a circulation hood
If you wish to use an appropriately
fi
tted
hood as a circulation hood, you must
mount the active carbon
fi
lter(s) to the
fan motor before using the hood. The ac-
tive carbo
n fi
lter(s) is/are included in the
scope of supply with some models.
Otherwise you must obtain the active
carbon
fi
lter(s) from the supplier of your
extractor hood. You must also change
your hood over to the „Filter position“ at
the device provided (lever or ball hand-
le).
7.4 Electrical connection
Before connecting the extractor hood,
check that the voltage stated on the ra-
ting plate (V) agrees with the supply vol-
tage in your home.
If the appliance is not
fi
tted with a con-
nector plug, a two-pole switch, confor-
ming to standards with a minimum open
contact gap of 3 mm is to be installed by
an authorized tradesman in an easily ac-
cessible location.
7.5 Mounting the carbon filter
You will
fi
nd the mounting instructions
for the carbon
fi
lter in its packaging. To
mount the carbon
fi
lter, remove the gre-
ase
fi
lter(s),
fi
t the carbon
fi
lter according
to its mounting instructions and re
fi
t the
greas
e fi
lter(s).
Installation
!
Never install the appliance if the data
on the rating plate does not agree with
your supply voltage.
You will
fi
nd the rating plate inside the
appliance, behind the greas
e fi
lter.
If the extractor hood is
fi
tted with a
standard connector plug, connect this
to an easily accessible standard socket.