Strona 8 z 11
rev. 1.0.1
USER MANUAL
:
KIVOS KVA01
INTELLIGENT HOME ALARM CAMERA
www.elmic.pl
,
Storage card
This product use T-flash card as external storage device, when there is no storage card in the product, the photo-taking
and video-recording functions are unrealizable.
If a self-provided storage card is used:
Up to 32G storage card is supportable.
1.
This machine has an automatic cycle and storage capabilities. When the card is full, it will overshadow the original
file. Then the number of new file will continue to put in.
2.
The serial number of TF card setted by this machine has 4 digits, maximum of 9999. When the follow-up file can not
be numbered and writted with ID, it should format. The new number will become from 0001. Before formatting,
please copy card content to a computer or other devices.
3.
The machine can be connected to the computer via a USB cable to output T card or to remove the T card through the
reader into the computer.
Note: Do not twist, squeeze, or crash the memory card, otherwise they may damage the image data recorded on the
card
Basic functions and use
1.
Function of body detection
The alarm adopts the integration of advanced design techniques of special processing chip of infrared sensor, the PIR dual
element pyroelectric infrared sensor, Fresnel lens and advanced digital remote sensing technology, micro-power ASIC and
automatic temperature compensation, control of the microprocessor decoder, and so on. Detection of infrared heat of
human radiation initiated the function of probe of audible alarm and video in the site.
Note: Fresnel lens of the probe should be kept clean
2.
Night-Vision
With Night-vision, even under the environment of extremely poor visibility, the system can automatically activate the
infrared lamp and take photo or record video of the objects or people within the distance of 10 meter; it displays black
and white effect under the environment of completely dark.
Note: keep the mirror surface of infrared lamp and optical sensor clean.
3.
Video and alarm
Turn on the power, green indicator light of power lights once, then enters the state of standby.
After buttoning “start” of remote control, green indicator light of host lights once, and video and alarm system starts
to work. Green indicator light lights in every 5 seconds indicates the normal self-test.
There are 20 seconds for delay in standby after start-up. Within 20 seconds, the alarm signal is not detected, so you must
leave of the detection region.
After 20 seconds if someone enters the detection area of annunciator which will have 5 seconds for delay to facilitate the
identification for the master. But if the identity of remote control signal is not received after 5 seconds, there will be
earpiercing alarm sounds giving 30seconds and meantime begin to video, and deposit TF card. It will alarm and video and
this process would repeat if staff went into the detection region after 5 seconds of the end of the alarm sound.
You can use the remote control to button the “start-up and close-up”, and then the green light even lights twice
in succession, the system is shut down, and the video and alarm end up.
4.
Only video, not alarm
Turn on the power switch, green indicator light of power lights once, then enters the state of standby.
After buttoning “start-up” of remote control, green indicator light of host lights once, and video and alarm system starts to
work. Green indicator light lights in every 5 seconds indicates the normal self-test.
After buttoning “elimination” of remote control, that green indicator light of host lights once indicates the received signal
and cancelled alarm function.
If someone enters the detection area of infrared warning devices which will have 5 seconds for delay to facilitate the
identification for the master. But if the identity of remote control signal is not received after 5 seconds, there would video
for 30seconds and storage in TF card. After video for 5 seconds if staff touched remote control of infrared warning devices
it would video again and the process would repeat.
After buttoning “alarm” of remote control, that the host of green indicator light brighter indicates that the signal has been
received, and alarm function has been restored.
You can use the remote control to button the “start-up and close-up”, and then the green light even brighter twice in
succession, the system is shut down, and the video and alarm end up.