16.

 

Code 

Enter  the  Code  Menu,  input  password  (0000).  If  the  password  is  wrong,  screen  shows  "Password  error!",  "Please  input 
again!", please input the right password. 
Match code function: match code; give code; receive code; inform: 

 
Match code 

(Outdoor unit should connect to the Indoor monitor) 

 

Select “Match Code” on indoor monitor -

press “

OK

” key-

enter into the match code mode 

 

Under the standby mode of outdoor unit -

long press “

call

” key-

 loosen key until the sound of a “Beep” , enter into 

the match code mode 

 

If  two  units  match  successfully  in  16  seconds,  indoor  monitor  displays  “Success”,  outdoor  unit  makes  “Beep-  Beep-
Beep” sounds, as the first outdoor unit 

 

If matching failed in 16 seconds, indoor monitor shows “failed”, the outdoor unit makes ”Beep” sound 

 

Press “

EXIT

” key on the indoor monitor, exit menu, enter into the standby mode 

Notice: If failed match, rematch the code after connection, otherwise, rematch the code after clear the code 

 
Indoor monitor clear code method: refer to the menu function -

code -

clear code. 

Outdoor unit clear code method: 
A. Transfomer supply: long press “Clear Code” key about one second, code cleared after a “tick” sound. 
B. Battery supply: press “Clear Code” key and “doorbell key” at the same time till a “Beep”, code cleared.  
 

Give code & Receive code 

(match more indoor monitors and outdoor units ): 

 

Choose “give code” on indoor monitor given or received code-

press “

OK

” key-

enter into “give code” mode 

 

Added  indoor monitor enters into the code  menu as above steps-

choose “receive code”  -

press “

OK

” key  -

  enter 

into the receive code mode. 

 

If code receiving finished in 16 seconds, exit code receiving mode after three “beep” sounds, and then enter into code 
menu. 

 

The added outdoor unit(finished clear code), under the standby mode-

keep pressing ”

call

” key for 6 seconds until two 

“beep” sounds(“beep” once about 3 seconds) -

loosen the key to enter into code receiving mode. 

 

Outdoor unit make three “beep” sounds if receive code successfully, and as No. 2 outdoor unit. 

 

If  failed  to  receive  code  in  16  seconds,  exit  receive  code  mode  after  one  “beep”  sound.  Enter  into  the  Code  Menu 
(Outdoor unit enters into the standby mode) 

 

After code receiving finished, press ”

OK

” key on code give unit to exit the code give mode, enter into the code menu. 

 

Press “

EXIT

” key to return to MENU gradually, then enter into standby mode 

 

After  all  units  receive  code  finished,  please  use  the  No.  2 outdoor  unit  call  all  indoor monitors,  if  all  code  matched, 
receive code successfully; if not, clear code of the new unit (don’t clear the code  giving unit), reform the code giving 
and code receiving again. 

 

Notice: 
1.Please don’t set same ID number for every indoor monitors and outdoor units. 
2.The original Password for code match menu is“0000”. 
3.Inform function: after match code, give code, receive code, clear code and reset ID number, please inform. Inform: tell 

all units the pieces and ID numbers in the system. 

4.Method of inform: outdoor unit calls all the indoor monitors (all indoor monitors should be matched), if there are two 

outdoor units, use the No. 2 outdoor unit to inform. 

 
Clear Code 

(Choose “code” option, press “

OK

” key to enter into password menu) 

 

Input the password to enter into code match menu (original password is 0000).If you input wrong password, system 
will  inform  you  “Password  Error!”,  “Please  Input  Again!”,  enter  into  the  code  match  menu  until  input  the  right 
password 

 

Press “

/

”key -

choose “Clear Code” -

 press “

OK

” key, enter into clear code menu. 

 

Press “

/

”key -

choose “Clear” (press “Back” to exit if you don’t want to clear anything ), system will return to code 

menu automatically after code clear confirmed 

 

Summary of Contents for KDB300

Page 1: ...Kuźnica 42 350 Koziegłowy Polska Poland NIP 627 114 97 86 REGON 240243739 www elmic pl elmic elmic pl USER MANUAL NAME MULTIPURPOSE WIRELESS VIDEO DOOR PHONE INTERCOM SYSTEM WITH MULTI MONITOR MODEL KIVOS KDB300 PLEASE READ THE INSTRUCTIONS BEFORE USING THE UNIT SAVE IT FOR USE IN THE FUTURE ...

Page 2: ...n space Battery equipped outdoor unit s proper monitoring function can replace Baby Monitor Introduction 3 Safety Warning Attention 3 1 Attention 3 2 Attention for operation of this product 3 3 Attentions for operation of charger 3 4 Operation and maintenance 4 Product Overview Model KDB300 4 1 Characteristics and application 4 2 Performance parameters 5 Product Diagram 6 Key introduction 7 Instal...

Page 3: ...he doctor immediately Do not dismantle or remodel this product otherwise damage creepage and electrical fault may be caused to this product Do not press the keys with a pin stump of pen pencil and other keen edged objects otherwise damage or mis operation will be caused Place tiny metal objects such as drawing pin at a place far away from the speaker As the speaker has magnetic property while work...

Page 4: ...opt European design full of modern science and technology feeling suitable for houses of various decorative styles Hidden antenna adopt built in antenna design protect the antenna effectively Extra large range of vision an extra wide angle viewable High resolution color LCD screen adopt 3 5 inch mainstream TFT digital LCD screen achieve outstanding clarity High resolution digital camera adopt 300 ...

Page 5: ...terproof grade IP55 Placement Hang on outwall Surface material ABS hardware accessories Camera 300 000 pixels View angle 120 wide angle Night vision pat tern 2 leds or Infrared lamps Working time 3 hours continuously Standby time 1000hours Charge time 3hours External Power DC5V 1A Indoor monitor Power Specific lithium battery BP 6M 1100mAh Consumption 400mA Outline dimension 126 84 20mm Weight 110...

Page 6: ...UAL KIVOS KD300 MULTIPURPOSE WIRELESS VIDEO DOOR PHONE INTERCOM SYSTEM WITH MULTI MONITOR www elmic pl elmic elmic pl Product Diagram Outdoor Unit Wall hung type holder and table type holder for Indoor monitor Indoor unit with monitor ...

Page 7: ...ance key for exposure adjust as option key when calling extension monitor 4 EXIT monitor key work as monitor key for standby mode as exit key for MENU one of the key to choose one way or both way talkback function 5 MENU unlock key work as unlock key when communicating with outdoor unit as right moving key for time setting MENU key for standby mode 6 Switch key ON OFF work as infrared lamps switch...

Page 8: ...e the picture push the bottom part make sure its steady and fix it from the bottom by screw then fit on the screw cover Unlocking Setting 1 Long press door bell until indicator blinks one time approx 9 seconds with a sound of Beep loosen the key right now unlocking time is set as 1 8 seconds Default unlock setting 2 Keep pressing until indicator blinks two times approx 3seconds more with two sound...

Page 9: ... card 3 Take out of the storage card push in the storage card until you hear a clicking sound then the storage card will pop up Storage Card Introduction This product adopts T flash card as external storage device when there is no storage card in the product the photo taking and video recording functions are unrealizable If a self provided storage card is used Please use a storage card with Class ...

Page 10: ...e outdoor unit can activate infrared lamps and recognize clearly objects or people within the distance of 1 5meter the best focus of this product is 0 8 meter If white LED configured the screen displays in color If Infrared lamp configured the screen displays in black and white Under connection condition of outdoor unit and indoor monitor press ON OFF key to activate infrared lamps on outdoor unit...

Page 11: ...eaking for indoor monitor but not for outdoor unit press OK to turn into both way communication red LED shuts down press monitor key again to turn back to one way voice monitor mode One or both way voice could be changed over repeatedly Intercom time is 90 seconds and shall be timed again after changing over Unlock in OK on state mode press unlock key after successful unlocking it shows unlock ico...

Page 12: ...essing EXIT in main menu 13 Video Turn into video menu and operate If there is no TF card screen displays No SD Card and turns back to main menu If there is TF card but no video record screen displays No File and turns back to main menu If there is TF card and video record screen displays video list by time order newest file is listed on the top Choose operating command Play Delete Delete All or B...

Page 13: ...er three beep sounds and then enter into code menu The added outdoor unit finished clear code under the standby mode keep pressing call key for 6 seconds until two beep sounds beep once about 3 seconds loosen the key to enter into code receiving mode Outdoor unit make three beep sounds if receive code successfully and as No 2 outdoor unit If failed to receive code in 16 seconds exit receive code m...

Page 14: ...less Own ID Number Enter into Own ID Number to set up ID Press key set up ID number press OK key confirm and exit ID Number setup menu Press EXIT key to turn back to standby mode step by step Notice Please don t repeat ID number for every indoor monitors and outdoor units Auto Control Enter into Auto Control to set up video Press key set up Auto video or Manual video press OK key to confirm and ex...

Page 15: ...e wallpaper after displaying the restore wallpaper return to Setup Menu Press EXIT key to turn back to standby mode step by step Version Enter into Version menu Press OK key to view version return to setup menu automatically in 2 seconds Press EXIT key to turn back to standby mode step by step Delete Alarm Notice Enter into Delete Alarm Notice Press OK key to delete alarm notice Screen shows Succe...

Page 16: ...e for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if...

Page 17: ...Adapter connector doesn t connect to charging port of machine correctly Reconnect correctly Adapter doesn t connect to 110V 240V alternating current Plug into the socket to connect to alternating current Doorbell no function Wire connection is not correct Check connection and reconnect Outdoor unit cannot call or connect to Indoor monitor Code match failed Clear code and re match code Image has no...

Reviews: