52
LP-520 REV. 7.26.16
Turn the dial
counterclockwise and clockwise to scroll through the displayed parameters. To view parameter details, press the
button at the appropriate screen. Press the
or
buttons to leave the parameter.
Press the
button again to return to Operation Mode.
To turn on Lock Mode, press the
button at the d:Lc parameter. Turn the dial
counterclockwise or clockwise to scroll On or Off.
Press the
button to save the selection and return to the parameters.
Press the
button again to return to Operation Mode.
NOTE:
The Control System will not allow the changes if Lock Mode is activated. Lock Mode will have to be turned off before making
further changes.
Parameter
Detail
Description
O: ot
Outdoor temperature
Current outdoor sensor temperature
A: Li or A: GA
DHW Water flow rate
Current flow (Li: LPM, GA: GPM)
b: It
CH return water temperature
Current CH return water temperature
C: Fr
FAN speed (RPM)
Current fan speed (RPM)
d: Lc
Lock function (Lock)
Lock Mode “ON”/”OFF”
E: oP
CH supply temperature (Operating temperature)
Current CH supply temperature
F: dH
DHW outlet temperature
Current DHW outlet temperature
H: Eh
Exhaust temperature
Current exhaust temperature
I: St
N/A
Not Used (Default is 0)
J: oH
CH water overheat temperature
Current temperature on the overheating sensor.
L: rt
1: PH
Burner Operation
Time
Supply power time
L:rt
display on
sub menu
Unit : 100 hour
2: rh
Burner operation time
Unit : 1 hour
3: rH
Burner operation time
Unit : 1,000 hour
4: It
Ignition cycles
Cycle : 10 times
5: IH
Ignition cycles
Cycle : 10,000 times
P: Ou
Displays output condition for internal primary pump and
three way valve.
- Off
- On
1
st
Icon
2
nd
Icon
3
rd
Icon
External Pump
Internal
Primary Pump
3 Way
Valve
Table 22
– Status Mode Display Screen Descriptions
I. INSTALLER MODE
Installer Mode will activate when the
button is pressed and held for five seconds while the display is powered OFF. If the display is
powered on, press the
button to turn it off before pressing and holding the
button for five seconds.
Figure 42
– Installer Mode Screens
Toggle through items that can be viewed/changed by turning the dial
. To view/change an item, press the
button. Some
displayed items can be changed by turning the dial
counterclockwise to lower and clockwise to raise the displayed value. Press the
button again to save settings.
To leave Installer Mode, press the
button again. The display will return to power off mode.
Summary of Contents for EFTC-140W
Page 2: ...2 LP 520 REV 7 26 16 ...
Page 20: ...20 LP 520 REV 7 26 16 Figure 8 Water Pressure vs Flow Through the Restrictors 140W Models ...
Page 35: ...35 LP 520 REV 7 26 16 Figure 24 Piping Legend ...
Page 44: ...44 LP 520 REV 7 26 16 Figure 32 Electrical Wiring Diagram ...
Page 45: ...45 LP 520 REV 7 26 16 Figure 33 Ladder Diagram ...
Page 88: ...88 LP 520 REV 7 26 16 ...
Page 89: ...89 LP 520 REV 7 26 16 ...