17
TCK3000
TCK6000
Figure 3-5
Hoist “Secondary Support” Configuration
3.8.3
NOTICE
See Section 7.7 for outdoor installation considerations.
3.9 Connecting Hoist to Air Supply
3.9.1
!
WARNING
HAZARDOUS AIR PRESSURE IS PRESENT IN THE HOIST, IN THE SUPPLY
OF COMPRESSED AIR TO THE HOIST, AND IN THE CONNECTIONS BETWEEN COMPONENTS.
Figure 3-6
Typical Air Supply Connection
3.9.2
Shut off the air supply and stop the airflow completely. Lock out and tag out in accordance with ANSI
Z244.1 “Personnel Protection – Lockout/Tagout of Energy Sources”.
3.9.3
!
CAUTION
Before connecting the air supply hose to the hoist, always purge the air hose to
clear any debris and water.
3.9.4
Apply approximately 10-15 drops (0.2-0.3 cc/min) of turbine oil (see approved lubricant under Section
6.0
Lubricants) into the hose before attaching to the hoist.
3.9.5
Make connections to air supply; reference Figure 3-6. Use a reducing adapter at the hoist valve
section for hose sizes larger than 3/4 inch NPT.
3.9.6
NOTICE
Where conditions dictate, the installation sequence can be reversed by mounting
the hoist first (Section 3.9) followed by connecting the air supply (Section 3.6).
3.10 Mounting the Hoist
3.10.1 Manual Trolley
– Follow instructions in Owner’s Manual provided with the trolley.
3.10.2 Motorized Trolley
– Follow instructions in Owner’s Manual provided with the trolley.