10
5.
Attach power supply connector from the range hood
to the connector on the blower motor assembly.
6.
Reinstall the heat lamp panel using the screws removed in
the “Preparing the Internal Blower System,” (2) in the sides
and either (3) in the back for the 36" (91.4 cm) model or (4)
in the back for the 48" (121.9 cm) model.
7.
Reconnect the electrical connector to the heat lamp.
8.
Go to the “Make Electric Power Supply Connection
to Range Hood” section.
Install Range Hood In-Line (External Type)
Blower Motor
NOTE:
Your range hood requires you to purchase an in-line
(external type) blower motor system. See “Blower Motor
System” in the “Accessories” section.
Prepare for Mounting the In-Line Blower System
The in-line blower system must be fastened to a secure
structure of the roof, ceiling, wall, floor, or new or existing
frame construction. The 4 holes on either the inlet (bottom)
side or the outlet (top) side of the blower must be used to
mount the in-line blower system to the structure.
NOTE:
The mounting hole locations must span the studs.
Additional stud framing may be required. Plywood may
be used to span open areas between ceiling joists or roof
rafters to aid installation. This structure must be strong
enough to support the weight of the in-line blower system
(50 lb [22.6 kg] min).
Prepare the In-line Blower System
1.
Using 2 or more people, move the in-line blower
motor system to the mounting location.
2.
Remove the 10 screws from the front cover of the
in-line blower motor housing and set them aside.
3.
Remove the front cover of the in-line blower motor
housing and set it aside.
NOTE:
To make the blower motor housing easier to
mount, the blower motor assembly can be removed.
If you do not want to remove the blower motor
assembly, proceed to “Install In-line Blower System”
in this section.
4.
Disconnect the motor electrical plug from the blower
motor assembly.
5.
Remove the screws that secure the blower motor
assembly to the in-line blower housing and set them aside.
6.
Pull the spring clip to release the blower motor assembly.
Remove the blower motor assembly from the housing and
place it on a covered surface.
B
A
A. Blower motor assembly connector
B. Power supply connector from range hood
A
B
A
A. Screws - panel mounting (5) for 36” (91.4 cm) models,
(6) for 48” (121.9 cm) models
B. Panel - Heat lamp
WARNING
Excessive Weight Hazard
Use two or more people to move and install in-line
blower motor system.
Failure to do so can result in back or other injury.
A
B C
D
C. Spring clip
D. Motor electrical plug
A. Front cover
B. Blower mounting screws