Flexible Metal Appliance Connector:

 

If local codes permit, a new CSA design-certified, 4 to 

5 ft (122 to 152.4 cm) long, 1/2" or 3/4" (1.3 or 1.9 cm) 

I.D. (inside diameter), flexible metal appliance connector 

may be used for connecting range to the gas supply line.

 

A 1/2" (1.3 cm) male pipe thread is needed for 

connection to the female pipe threads of the inlet to the 

appliance pressure regulator.

 

Do not kink or damage the flexible metal tubing when 

moving the range.

 

Must include a shut-off valve:
Install a manual gas line shut-off valve in an easily accessible 

location. Do not block access to shut-off valve. The valve is 

for turning on or shutting off gas to the range.

A

B

C

A.  Gas supply line
B.  Shut-off valve “open” position
C.  To range

Gas Pressure Regulator

The gas pressure regulator supplied with this range must be 

used. The inlet pressure to the regulator should be as follows  

for proper operation:

Natural Gas:

Minimum pressure: 5" (12.7 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP

Propane Gas:

Minimum pressure: 11" (28 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
Contact local gas supplier if you are not sure about the inlet 

pressure.

Burner Input Requirements

Input ratings shown on the model/serial/rating plate are for 

elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at 

a rate of 4% for each 1,000 ft (304.8 m) above sea level (not 

applicable for Canada).

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least 1" 

water column pressure above the manifold pressure shown on 

the model/serial/rating plate.

Line pressure testing above 1/2 psi (3.5 kPa)  

gauge (14" [35.5 cm] WCP)

The range and its individual shut-off valve must be disconnected 

from the gas supply piping system during any pressure testing of 

that system at test pressures in excess of 1/2 psi (3.5 kPa).

Line pressure testing at 1/2 psi (3.5 kPa)  

gauge (14" [35.5 cm] WCP) or lower

The range must be isolated from the gas supply piping 

system by closing its individual manual shut-off valve during 

any pressure testing of the gas supply piping system at test 

pressures equal to or less than 1/2 psi (3.5 kPa).

Summary of Contents for KSGB900ESS4

Page 1: ... Tip Bracket Is Installed and Engaged 13 Electronic Ignition System 13 Remove Replace Drawer 14 Oven Door 14 Complete Installation 15 GAS CONVERSIONS 16 Propane Gas Conversion 16 Natural Gas Conversion 19 Adjust Flame Height 22 SÉCURITÉ DE LA CUISINIÈRE 24 EXIGENCES D INSTALLATION 26 Outils et pièces 26 Exigences d emplacement 26 Spécifications électriques 29 Spécifications de l alimentation en ga...

Page 2: ...proved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any othe...

Page 3: ...lled Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of the anti tip bracket Re engage anti tip bracket if range is moved Do not operate range without anti tip bracket installed and engaged Failure to follow these instructions can result in death or serious burns to children and adults Anti Tip Bracket To verify the...

Page 4: ...rial rating plate The model serial rating plate is located behind the oven door on the top right hand side of the oven frame The range should be located for convenient use in the kitchen Recessed installations must provide complete enclosure of the sides and rear of the range All openings in the wall or floor where range is to be installed must be sealed Cabinet opening dimensions that are shown m...

Page 5: ...securing the range is adequate as long as it conforms to the standards listed above Product Dimensions This manual covers several models Your model may appear different from the models depicted Dimensions given are maximum dimensions across all models IMPORTANT Range must be level after installation Follow the instructions in the Level Range section Using the cooktop as a reference for leveling th...

Page 6: ...rd covered with not less than No 28 MSG sheet steel 0 015 0 4 mm stainless steel 0 024 0 6 mm aluminum or 0 020 0 5 mm copper 30 76 2 cm minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet A 18 45 7 cm upper side cabinet to countertop B 13 33 cm max upper cabinet depth C 30 76 2 cm min opening width D For minimum clearance to top of cookto...

Page 7: ... is grounded Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock WARNING Gas Supply Requirements Observe all governing codes and ordinances IMPORTANT This installation must conform with all local codes and ordinances In the absence ...

Page 8: ...14 35 5 cm WCP Propane Gas Minimum pressure 11 28 cm WCP Maximum pressure 14 35 5 cm WCP Contact local gas supplier if you are not sure about the inlet pressure Burner Input Requirements Input ratings shown on the model serial rating plate are for elevations up to 2 000 ft 609 6 m For elevations above 2 000 ft 609 6 m ratings are reduced at a rate of 4 for each 1 000 ft 304 8 m above sea level not...

Page 9: ...e people to move and install range Failure to do so can result in back or other injury Install Anti Tip Bracket 1 Remove the anti tip bracket from the inside of the oven 2 Determine which mounting method to use floor or wall If you have a stone or masonry floor you can use the wall mounting method If you are installing the range in a mobile home you must secure the range to the floor This anti tip...

Page 10: ...unter to the floor 3 Measure the distance from the top of the cooktop to the bottom of the leveling legs This distance should be the same If it is not adjust the leveling legs to the correct height The leveling legs can be loosened to add up to a maximum of 1 2 5 cm A minimum of 3 16 5 mm is needed to engage the anti tip bracket NOTE If height adjustment is made when range is standing tilt the ran...

Page 11: ...two figures below depending on the size of the level Check with the level side to side and front to back 2 If range is not level use a wrench or pliers to adjust leveling legs up or down until the range is level NOTE Range must be level for satisfactory baking performance and best cleaning results using AquaLift Self Clean Technology 3 Use a 15 16 2 4 cm combination wrench and an adjustable wrench...

Page 12: ...rong size burner cap on the burner base Each round burner cap is marked with an AUX SR UR or ST to match with a letter on the burner base 7 Plug into a grounded 3 prong outlet A B C D E A Burner cap B Gas tube opening C Burner base D Igniter electrode E Orifice holder A B A Incorrect B Correct Electrical Shock Hazard Plug into a grounded 3 prong outlet Do not remove ground prong Do not use an adap...

Page 13: ...Check that the range is level by placing a level on the oven bottom See the Level Range section IMPORTANT If the range is moved to adjust the leveling legs verify that the anti tip bracket is engaged by repeating steps 1 to 8 Electronic Ignition System Initial Lighting and Gas Flame Adjustments Cooktop and oven burners use electronic igniters in place of standing pilots When the cooktop control kn...

Page 14: ...f the oven controls Remove Replace Drawer on some models Remove all items from inside the baking drawer warming drawer or premium storage drawer and then allow the range to cool completely before attempting to remove the drawer To Remove 1 Open the drawer to its fully open position 2 Using a flat blade screwdriver gently loosen the drawer from the glide alignment notch and then lift up the drawer ...

Page 15: ...o remove waxy residue caused by shipping material Dry thoroughly with a soft cloth For more information see the Range Care section of the User Guide 7 Read the User Guide 8 Turn on surface burners and oven See the User Guide for specific instructions on range operation NOTE Odors and smoke are normal when the oven is used the first few times If Range Does Not Operate Check the Following Household ...

Page 16: ...ulator Natural Gas to Propane Gas 1 Remove the premium storage drawer warming drawer or baking drawer See the Remove Replace Drawer section 2 Locate gas pressure regulator at rear of the drawer compartment IMPORTANT Do not remove the gas pressure regulator WARNING Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to floor or wall per installation instruction...

Page 17: ...remove by turning it counterclockwise and lifting out Set gas orifice spud aside 4 Remove the orifice spuds shipped in the literature package in the oven Gas orifice spuds are stamped with a number and have a groove in the hex area Replace the Natural gas orifice spud with the correct Propane gas orifice spud Refer to the following chart for correct Propane gas orifice spud ratings and to spud hol...

Page 18: ... 7 Replace the 47 spud with a 56 spud Install the Propane gas bake burner orifice spud turning it clockwise until snug IMPORTANT Do not overtighten 8 Position the back of the bake burner over the oven orifice and then align the holes for the screws 9 Reattach the bake burner with 2 screws 10 Position the front of the oven bottom panel toward the front frame and then lower the rear of the oven bott...

Page 19: ...tinct as the inner cone Propane gas flames have a slightly yellow tip 4 Refer to Complete Installation in the Installation Instructions section of this manual to complete this procedure IMPORTANT Make sure to save the orifices that have just been replaced in the conversion Natural Gas Conversion 1 Turn the manual shut off valve to the closed position 2 Unplug range or disconnect power To Convert G...

Page 20: ...turning it counterclockwise and lifting out Set gas orifice spud aside 4 Gas orifice spuds are stamped with a number on the side Replace the Propane gas orifice spud with the correct Natural gas orifice spud 5 Remove choke from x large burner base Refer to the following chart for the correct Natural gas orifice spud placement Natural Gas Orifice Spud Chart Burner Rating Size mm ID Number 19 000 BT...

Page 21: ...en bottom A B A Bake burner B Screws A A Oven orifice 7 Replace the 56 spud with a 47 spud Install the Natural gas bake burner orifice spud turning it clockwise until snug IMPORTANT Do not overtighten 8 Position the back of the bake burner over the oven orifice and then align the holes for the screws 9 Reattach the bake burner with 2 screws 10 Position the front of the oven bottom panel toward the...

Page 22: ...top bake and broil burner flame is very important Natural gas flames do not have yellow tips 4 Refer to Complete Installation in the Installation Instructions section of this manual to complete this procedure x x x A A Orifice hood IMPORTANT Make sure to save the orifices that have just been replaced in the conversion Adjust Flame Height Adjust Surface Burner Flame Adjust the height of top burner ...

Page 23: ...ven bottom The oven bake burner should light within 8 seconds Under certain conditions it may take the burner up to 50 to 60 seconds to light Electronic igniters are used to light the bake and broil burners This flame should have a 1 2 1 3 cm long inner cone of bluish green with an outer mantle of dark blue and should be clean and soft in character No yellow tips blowing or lifting of flame should...

Page 24: ...W11399120A 2019 All rights reserved Used under license in Canada Tous droits réservés Utilisé sous licence au Canada 11 19 ...

Reviews: