KitchenAid KPED892K Installation Instructions And Use And Care Manual Download Page 3

Now start...

Excessive Weight Hazard

Use two or more people to move
and install external blower.

Failure to do so can result in
back or other injury.

WARNING

1.

Discard any cardboard packaging

from the blower wheel.

2.

Remove wiring box cover and

screws.

3.

Attach an appropriate U.L./CSA-

listed strain relief in the hole at the rear
of the wiring box.

Follow the instructions for your type of
installation.

WALL INSTALLATIONS

ROOF INSTALLATIONS

1.

Choose a location on an outside 

wall where no wall studs, wires, pipes,
etc. run through the opening area. A
minimum distance of 24" (61 cm) from
exterior blower to ground may be
required depending on local code.
Make sure to leave room for anticipated
snowfall in your region.

2.

Drill the guide hole in the center

of the 11" (27.9 cm) diameter opening
area.

3.

Mark a 27-1/2" x 34" (69.9 x 

86.4 cm) rectangle on wall as indicated
in FIGURE 1.

4.

Cut a rectangular hole in the

siding only. Do not cut sheathing. Nail
down all siding ends.

5.

Mark an 11" (27.9 cm) diameter

circle around Guide Hole as indicated
in FIGURE 1. Mark center of the 
1-1/4" (or 3.0 cm) diameter hole for
electrical wiring as indicated in
FIGURE 1.

6.

Cut 11" (27.9 cm) diameter hole

in sheathing. Drill the 1-1/4" (or 3.0
cm) diameter electrical wiring hole.

7.

Run a large bead of caulk on the

back side of the housing along the outer
edge.

8.

Center the exterior blower ring in

the 11" 

(27.9 cm) 

diameter hole, making

sure that the 1-1/4" (or 3.0 cm) diameter
electrical wiring hole lines up with the
hole in the wiring box.

9.

Attach the exterior blower to wall

using screws appropriate for your
installation. All four holes in the back
panel must be filled to prevent moisture
that may get inside the 

exterior

blower

housing from leaking into the home.

10.

Seal all around the mounting

screw heads with caulk.

FIGURE 1

FIGURE 2

34"

(86.4 cm)

15"

(38.1 cm)

10-5/8"

(27 cm)

1-1/4"

(3.0 cm)

dia. hole

9-3/8"

(23.8 cm)

14"

(35.6 cm)

9-3/8"

(23.8 cm)

23"

(58.4 cm)

12-3/4"

(32.4 cm)

10-5/8"

(27 cm)

1-1/4"

(3.0 cm)

dia. hole

11" (27.9 cm)

dia. hole

guide

hole

guide

hole

11" (27.9 cm)

dia. hole

27-1/2" (69.9 cm)

13-3/4"

(34.9 cm)

25" (63.5 cm)

1.

Choose location on rear slope of

roof that minimizes vent run. Avoid
obstacles such as TV leads, electric
lines, etc. If 

exterior

blower top is level

with roof peak, it will not be seen from
street. Remember this location as you
work from inside the attic.

2.

Mark a point half-way between

the rafters and drill a guide hole at this
point.

3.

From the outside, using the guide

hole as a starting point, mark the
rectangular cut-out as indicated in
FIGURE 2. Remove ONLY the shingles
in THIS AREA.

4.

Mark an 11" (27.9 cm) diameter

circle around guide hole as indicated in
FIGURE 2. Mark center of the 1-1/4"
(or 3.0 cm) diameter hole for the
electrical wiring as indicated in 
FIGURE 2.

5.

Cut out the roof boards along the

11" (27.9 cm) diameter circle. Drill the 
1-1/4" (or 3.0 cm) diameter electrical
wiring hole.

Page 3

11.

Go to "Making electrical and

vent connections", Page 4.

Summary of Contents for KPED892K

Page 1: ... ordinances Important Observe all governing codes and ordinances It is the customer s responsibility To contact a qualified electrical installer To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinan...

Page 2: ...e exterior blower should be centered between wall studs or roof rafters The size of the vent system should be uniform Do not install two elbows together Use duct tape to seal all joints in the vent system Use caulking to seal exterior wall or floor opening around the cap Flexible vent is not recommended It creates back pressure air turbulence and greatly reduces performance Make sure there is prop...

Page 3: ... the 11 27 9 cm diameter hole making sure that the 1 1 4 or 3 0 cm diameter electrical wiring hole lines up with the hole in the wiring box 9 Attach the exterior blower to wall using screws appropriate for your installation All four holes in the back panel must be filled to prevent moisture that may get inside the exterior blower housing from leaking into the home 10 Seal all around the mounting s...

Page 4: ...that may get inside the remote blower housing from leaking into the home 9 Seal all the shingles around the exterior blower housing flashing sheet and mounting screw heads or frame with Electrical Shock Hazard Disconnect power before making electrical connections Connect the ground wire to green ground screw in wiring box Failure to do so can result in death or electrical shock WARNING 1 Remove th...

Page 5: ...Aid E Repairs to parts or systems resulting from unauthorized modifications made to the appliance F Replacement parts or repair labor costs for units operating outside the United States or Canada G In Canada travel or transportation expenses for customers who reside in remote areas KITCHENAID AND KITCHENAID CANADA DO NOT ASSUME ANY RESPONSIBILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states...

Page 6: ... impaired limited vision etc Referrals to local dealers service companies and repair parts distributors KitchenAid designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the designated KitchenAid service company in your area you can also look in your telephone directoryYellow Pages 1 If you need assistan...

Page 7: ... permet on recommande qu un électricien qualifié vérifie que la liaison à la terre est adéquate Ne pas utiliser une tuyauterie de gaz pour la liaison à la terre En cas d incertitude quant à la qualité de la liaison à la terre de la hotte consulter un électricien qualifié Ne pas installer un fusible en série avec le conducteur neutre ou le conducteur de liaison à la terre IMPORTANT Avant d entrepre...

Page 8: ...d aspiration vers le bas pour qu il soit possible d y raccorder le conduit rond de 25 4 cm 10 po Veiller à ce qu il y ait un espace disponible suffisant pour tout raccord de transition qu il serait nécessaire d installer entre le ventilateur extérieur et le système de raccordement Pour optimiser la performance placer tout raccord de transition nécessaire aussi près que possible de la hotte ou du s...

Page 9: ...collerette du ventilateur extérieur sur l ouverture de dia 27 9 cm 11 po veiller à ce que le trou de 3 cm 1 1 4 po pour le passage du câble électrique soit aligné avec le trou de passage dans la boîte de raccordement du câblage 9 Fixer le ventilateur extérieur sur le mur avec des vis de taille appropriée Obturer les quatre trous du panneau arrière pour éviter l introduction d humidité dans la rési...

Page 10: ...pour assurer l étanchéité entre les bardeaux et le ventilateur tout autour de la caisse du ventilateur au niveau du solin et sur les têtes de vis au niveau de la structure de support Risque de choc électrique Interrompre l alimentation électrique avant d effectuer des raccordements Connecter le conducteur de liaison à la terre avec la vis verte dans la boîte de connexion Le non respect de ces inst...

Page 11: ...n autorisées effectuées sur l appareil F Coût de pièces de rechange ou de main d œuvre de réparation pour des appareils utilisés en dehors des États Unis ou du Canada G Au Canada frais de déplacement ou de transport pour les clients qui résident dans des régions éloignées KITCHENAID ET KITCHENAID CANADA NE SONT PAS RESPONSABLES POUR LES DOMMAGES FORTUITS OU INDIRECTS Certains États ou certaines pr...

Page 12: ...les sont fabriquées selon les mêmes spécifications précises utilisées pour construire chaque nouvel appareil KitchenAid Pour localiser des pièces autorisées par l usine dans votre région téléphonez à notre Centre d interaction avec la clientèle votre Centre de service autorisé le plus proche ou le service de l usine KitchenAid en composant le 1 800 442 1111 Pour plus d assistance Si vous avez beso...

Reviews: