background image

CUTOUT DIMENSIONS FOR OVENS INSTALLED UNDER COOKTOP

IMPORTANT: Observe all governing codes and ordinances. Cooktop must be approved for use over an oven. See cooktop Installation 
Instructions for cutout dimensions. Center the cooktop cutout over oven cutout.

To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, 
delaminate or sustain other damage. This oven has been designed in accordance with UL and CSA International and complies with the 
maximum allowable wood cabinet temperatures of 194°F (90°C).

Approved Built-In Oven and Electric Radiant/Coil Cooktop Combinations

For the approved model number combinations, refer to the undercounter label located on top of the oven chassis and on the 
bottom of the cooktop burner box.

NOTE: For undercounter installation, it is recommended that the junction boxes for oven and cooktop be located in the adjacent right or 
left cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface 
to pass the appliance cable through to the junction box. On models with Steam-Assist, it will be necessary to drill a ½" (1.3 cm) 
minimum diameter hole in the upper right or left rear corner of the side wall to pass the water supply tubing through to the undersink 
water filter. If water supply tubing hole is drilled on the same side as the oven cable hole, a minimum of 2" (5.1 cm) is required between 
the 2 holes.

A. 24" (61 cm) cabinet depth
B. 25" (63.5 cm) countertop depth

C. Recommended oven and cooktop junction box locations
D. Allow 

⁵⁄₈

" (1.6 cm) for oven trim to overlap on each side.

E. 27¾" (70.5 cm) minimum cutout height

F. 36" (91.4 cm) from cabinet base to countertop

G. 4

⁵⁄₈

" (11.7 cm) maximum from cabinet base

H. See Cutout Dimensions chart.

I. 31

³⁄₈

" (79.7 cm) from top of countertop to bottom of cutout

CUTOUT DIMENSIONS

Oven Size

Oven Cutout Dimension

24" (61 cm)

22

¹⁄₂

" (57.2 cm)

27" (68.6 cm)

25

¹⁄₂

" (64.8 cm)

30" (76.2 cm)

28½" (72.4 cm)

36" (91.4 cm)

34

¹⁄₂

" (87.6 cm)

A

E

F

G

H

B

C

C

D

I

W10373101B

Summary of Contents for KICU509XSS

Page 1: ...d in the adjacent right or left cabinet A 1 2 5 cm minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface to pass the appliance cable through to the junction box On models with Steam Assist it will be necessary to drill a 1 3 cm minimum diameter hole in the upper right or left rear corner of the side wall to pass the water supply tubing throu...

Page 2: ... left rear corner of the side wall to pass the water supply tubing through to the undersink water filter If water supply tubing hole is drilled on the same side as the oven cable hole a minimum of 2 5 1 cm is required between the 2 holes A 24 61 cm cabinet depth B 25 63 5 cm countertop depth C Recommended oven and cooktop junction box locations D Allow 1 6 cm for oven trim to overlap on each side ...

Page 3: ...lt grounded outlet for cooktop Lower shaded areas are recommended locations for flexible or rigid gas pipe installation The gas connection on the cooktop is on the right same location as J in the above diagram The gas pipe can be installed on either side of the cutout and either through the floor or through the wall Refer to local codes regarding the use of gas lines A 24 61 cm cabinet depth B 1 2...

Page 4: ...4 Notes ...

Page 5: ...four et table de cuisson soient situés dans le placard adjacent à droite ou à gauche Un trou de diamètre 1 2 5 cm ou plus doit avoir été percé dans la partie supérieure de l angle arrière gauche ou droit de la surface de la paroi latérale pour le passage du câble d alimentation de l appareil jusqu au boîtier de connexion Sur les modèles avec injection de vapeur il faudra percer un trou d un diamèt...

Page 6: ...la paroi latérale pour le passage de la canalisation d eau jusqu au filtre à eau sous l évier Si le trou de la canalisation d eau est percé du même côté que celui du câble du four une distance minimale de 2 5 1 cm est nécessaire entre les 2 trous A Profondeur de placard 24 61 cm B Profondeur du plan de travail 25 63 5 cm C Emplacements recommandés pour le boîtier de connexion du four et de la tabl...

Page 7: ...isation de gaz flexible ou rigide dans la zone ombrée inférieure Le point de raccordement au gaz de la table de cuisson se trouve sur la droite même emplacement que le point J dans le schéma ci dessus La canalisation de gaz peut être installée d un côté ou de l autre de l ouverture découpée à travers le plancher ou à travers le mur Consulter les codes locaux concernant l utilisation des canalisati...

Page 8: ...W10373101B 2011 All rights reserved Tous droits réservés 5 11 Printed in U S A Imprimé aux É U ...