background image

Summary of Contents for KICU265HBT1

Page 1: ...r future reference Save Installation Instructions for local electrical inspector suse 4329223 9763387 Quick Reference Table of Contents Pages Before you start Product dimensions Cabinet dimensions Venting requirements Electrical requirements _ installation steps Use and Care information Wiring diagram Accessories Warranty _ Requesting Assistance or Service ...

Page 2: ...nings in ceiling and wall where range hood wUl be installed must be sealed WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURYTO PERSONS OBSERVE THE FOLLOWING Installation work and electrical wiring must be done by qualified person s in accordance with all applicable Codes and Standards including Fire Rated Construction The combustion airflow needed for safe operation of fuel burning equip...

Page 3: ... foil vent 3 36 91 4 cm base cabinet height For the most efficient and quiet operation it is recommended that the range hood be vented vertically through the roof through 9 22 9 cm round metal ventwork The size of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used Do Not install two...

Page 4: ... 25 cm the roof through the wall jJ Note 3 1 4 x 10 8 3 cmx 25 cm rectangular vent must be used inside chimney cover Round vent wiJJ net fit inside chimney cover wall cap Calculating the vent system length To calculate the length of the system you need add the equivalent feet for each vent piece used in the system Vent Piece 45 elbow 90 elbow 90 flat elbow transition to round wall cap 3 1 4 x 10 8...

Page 5: ...ned from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Preparation Because of the size and weight of this island canopy hood the support sys tem must be securely attached to the ceiling For piaster or sheet rock ceilings the support must be attached to joists if this is not possible you m...

Page 6: ...knockout using a flat blade screwdriver Do not remove optional remote blower knockout Attach conduit connector into power supply cable opening so that conduit connector clamping screws are inside the terminal box Excessive Weight Hazard Use two or more people to move and install island canopy hood Failure to do so can result in back or other injury slot 1 4 6 4 ram 1 Loosen four bolts located next...

Page 7: ...nopy ni so rear edge is over flange Press filters up into position Check operation 17 Turn power on control panel location The island canopy hood controls are located in a grey panel on underside of the canopy To open the panel press on the front edge of panel and release The control panel will drop down o lr 4Ole 1 r_01 light switch 40 tll 11111111111111 F blower blower speed switch switch Check ...

Page 8: ...seanextinguisher ONLY if Youknowyouhavea Class ABC extinguisher andyoualready knowhowto operateit Thefire is smallandcontainedin the areawhereit is started Thefire department is being called Youcanfight thefirewith your backto anexit Thisfansuitable for usewithsolid state speed controls Operation The islandcanopy hood is designed to remove smoke cooking vapors and odors from the cooktop area For b...

Page 9: ... the cover all the way to the right Position the left end of the light cover over the flange and slide the cover back to left Reinstall the retainer clips retainer clips support flange F I BLKI _I LINE IN t2 URC _1 6 Hz Note If a remote blower is used with this range hood current draw must not exceed 4 amps Note Instructions are included with each kit Utensil Bar Part No 4378619 15 38 cm long stai...

Page 10: ... resulting from unauthorized modifications made to the appliance 8 Expenses for travel and transportation for product service in remote locations 9 The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLU...

Page 11: ...rs KitchenAid designated service technicians are trained to fulfill the product warranty and provide after warranty service anywhere in the United States To locate the designated KitchenAid service company in your area you can also look in your telephone directoryYellow Pages if you need replacement parts If you need to order replacement parts we recom mend that you only use factory authorized par...

Page 12: ...pliance s complete model and serial numbers and the purchase date This information will help us respond properly to your request KitchenAidCanada Appliance Service Consumer Services Direct service branches BRITISH COLUMBIA 1 800 665 6788 ALBERTA 1 800 661 6291 ONTARIO Ottawa area 1 800 267 3456 except 807 area code Outside the Ottawa area 1 800 807 6777 MANITOBA SASKATCHEWAN 1 800 665 1683 and 807...