KitchenAid KGCC506RWW - 30

3

The gas and electric supply should be located as shown in 
“Installation Clearances” section so that they are accessible 
without requiring removal of the cooktop.

Provide cutout in right rear corner of cutout enclosure as 
shown to provide clearance for gas inlet, power supply cord, 
and to allow the rating label to be visible.

IMPORTANT: To avoid damage, check with your builder or 
cabinet supplier to make sure that the materials used will not 
discolor, delaminate or sustain other damage.

Mobile Home - Additional Installation Requirements

The installation of this cooktop must conform to the Manufactured 
Home Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction and 
Safety, Title 24, HUD Part 280). When such standard is not 
applicable, use the Standard for Manufactured Home 
Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this cooktop must conform with the 
current standards CAN/CSA-A240-latest edition, or with local 
codes.

Product Dimensions

Metal Cooktops

Straight-edge glass cooktops

Curved-edge glass cooktops

Installation Clearances

NOTES: After making the countertop cutout, some installations 
may require notching down the base cabinet side walls to clear 
the burner box. To avoid this modification, use a base cabinet with 
sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the 
countertop to the top of the drawer (or other obstruction) in base 
cabinet is required. The drawer depth may need to be shortened 
to avoid interfering with the regulator.
If installing a hood above the range, follow the hood instructions 
for dimensional clearances above the cooktop surface.

A. 21

¹⁄₄

" (53.4 cm)

B. 31

⁷⁄₁₆

" (79.8 cm) on 30" (76.2 cm) models, 

37

⁹⁄₁₆

" (95.4 cm) on 36" (91.4 cm) models

C. 2

⁷⁄₈

" (7.3 cm)

A. 20

⁵⁄₁₆

" (51.5 cm)

B. 30

³⁄₁₆

" (76.8 cm) on 30" (76.2 cm) models, 

36

⁷⁄₁₆

" (92.5 cm) on 36" (91.4 cm) models

C. 2

⁷⁄₈

" (7.3 cm)

A. 21

¹⁄₈

" (53.7 cm)

B. 30

⁵⁄₁₆

" (77.0 cm) on 30" (76.2 cm) models, 

36

⁵⁄₁₆

" (92.3 cm) on 36" (91.4 cm) models

C. 2

⁷⁄₈

" (7.3 cm)

A

B

C

C

A

B

A

B

C

A. 30

"

 (76.2 cm) on 30

"

 models; 36

"

 (91.4 cm) on 36

"

 models

B. Combustible area above countertop (shown by dashed box 

above)

C. 30

"

 (76.2 cm) minimum clearance between top of cooktop 

platform and bottom of unprotected wood or metal cabinet 
(24

"

 [61 cm] minimum clearance if bottom of wood or metal 

cabinet is protected by not less than 

¹⁄₄

"

 [0.6 cm] flame 

retardant millboard covered with not less than No. 28
MSG sheet steel, 0.015

"

 [0.04 cm] stainless steel, or 

0.024

"

 [0.06 cm] aluminum or 0.020

"

 [0.05 cm] copper)

D. 13

"

 (33 cm) maximum upper cabinet depth

E. 2

¹⁄₈

"

 (5.4 cm)

F. 19

"

 (48.3 cm)

G. 18" (45.7 cm) minimum clearance from upper cabinet to 

countertop within minimum horizontal clearances to cooktop

H. Grounded outlet - Locate within 24" (61 cm) of right rear 

corner of cutout

I. 29" (73.7 cm) on 30" models; 35¼" (89.5 cm) on 36" models

J. 8

³⁄₈

" (21.3 cm) minimum distance to nearest left and right side 

combustible surface

K. 2

⁷⁄₈

" (7.3 cm) minimum distance to rear combustible surface

L. Gas line opening - Wall: anywhere 5" (12.7 cm) below 

underside of countertop. Cabinet floor: anywhere within 
6" (15.2 cm) of rear wall is recommended

M. 24" (61 cm) minimum countertop depth is required

B

D

A

C

E

F

H

I

J

G

K

L

M

Summary of Contents for KGCC506RWW - 30" Gas Cooktop

Page 1: ...llation instructions with the homeowner Homeowner Keep installation instructions for future reference Save installation instructions for local electrical inspector s use IMPORTANT Installateur Remettre les instructions d installation au propriétaire Propriétaire Conserver les instructions d installation pour référence ultérieure Conserver les instructions d installation pour consultation par l ins...

Page 2: ...en dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The cooktop is designed to hang from the countertop by its side or rear flanges WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to preve...

Page 3: ...r obstruction in base cabinet is required The drawer depth may need to be shortened to avoid interfering with the regulator If installing a hood above the range follow the hood instructions for dimensional clearances above the cooktop surface A 21 53 4 cm B 31 79 8 cm on 30 76 2 cm models 37 95 4 cm on 36 91 4 cm models C 2 7 3 cm A 20 51 5 cm B 30 76 8 cm on 30 76 2 cm models 36 92 5 cm on 36 91 ...

Page 4: ...er conversion for use with LP gas This cooktop is factory set for use with Natural gas To convert to LP gas see the Gas Conversion instructions provided in the literature package The model serial rating plate located on the underside of the burner box has information on the types of gas that can be used If the types of gas listed do not include the type of gas available check with the local gas su...

Page 5: ... inlet pressure Burner Input Requirements Input ratings shown on the model serial rating plate are for elevations up to 2 000 ft 609 6 m For elevations above 2 000 ft 609 6 m ratings are reduced at a rate of 4 for each 1 000 ft 304 8 m above sea level not applicable for Canada Gas Supply Pressure Testing Line pressure testing above psi gauge 14 WCP The cooktop and its individual manual shutoff val...

Page 6: ... hold brackets in place when cooktop is put in cutout 7 Turn the cooktop right side up and place in cutout NOTE Make sure that the front edge of the cooktop is parallel to the front edge of the countertop If repositioning is needed lift entire cooktop up from cutout to prevent scratching the countertop 8 Loosen the screws and rotate the brackets so that they are perpendicular to the edge of the bu...

Page 7: ...ulator and the other adapter and nipple to the gas shutoff valve Tighten both adapters and nipples 3 Use a combination wrench and channel lock pliers to attach the flexible connector to the adapters Check that connector is not kinked Complete Connection 1 Open the manual shutoff valve in the gas supply line The valve is open when the handle is parallel to the gas pipe 2 Test all connections by bru...

Page 8: ...ing the proper burner operation turn the control knobs to OFF If burners do not light properly Turn surface burner control knob to the OFF position Check that the power supply cord is plugged in and the circuit breaker has not tripped or the fuse blown Check that the gas shutoff valves are set to the open position Check that burner caps are properly positioned on burner bases Recheck operation of ...

Page 9: ...RAL 5 16 WIDE BLADE BK BK PLUG LINE GROUND CONNECT 250 TERMINALS GROUND SPARK MODULE 120 VAC 60 Hz 1 PHASE 15 OR 20 AMP VALVE SWITCHES ROUND BLADE IGNITER ELECTRODES ELECTRIC CIRCUIT CLOSED WHEN KNOB IS ROTATED 55 TO 95 COUNTERCLOCKWISE FROM OFF 1 4 WIDE BLADE W GND 5 Y OR BR 5 PLACES SWITCHES ON VALVES 4 3 2 1 N L1 BK G OR G Y G OR G Y NEUTRAL 5 16 WIDE BLADE BK BK PLUG LINE 1 4 WIDE BLADE GROUND...

Page 10: ...essures graves à vous et à d autres Tous les messages de sécurité suivront le symbole d alerte de sécurité et le mot DANGER ou AVERTISSEMENT Ces mots signifient AVERTISSEMENT Pour votre sécurité les renseignements dans ce manuel doivent être observés pour réduire au minimum les risques d incendie ou d explosion ou pour éviter des dommages au produit des blessures ou un décès Ne pas entreposer ni u...

Page 11: ...inimales des dégagements de séparation Une source d électricité avec liaison à la terre est nécessaire Voir la section Spécifications électriques Une source de gaz adéquate doit être disponible Voir la section Spécifications de l alimentation en gaz De par sa conception la table de cuisson est suspendue sur le plan de travail par les rebords des côtés ou de l arrière Veiller à placer les sources d...

Page 12: ...2 cm sur les modèles de 30 36 91 4 cm sur les modèles de 36 B Zone de matière combustible au dessus du plan de travail espace délimité par des lignes pointillées ci dessus C Distance de séparation de 30 76 2 cm ou plus entre le plan de travail et le fond d un placard métallique ou de bois non protégé distance de séparation de 24 61 cm ou plus si le fond du placard de métal ou de bois est protégé p...

Page 13: ...en vigueur National Fuel Gas Code ANSI Z223 1 ou CAN CGA B149 Type de gaz Gaz naturel La conception de cette table de cuisson a été homologuée par CSA International pour l alimentation au gaz naturel ou pour l alimentation au propane après conversion adéquate Cette table de cuisson a été configurée à l usine pour l alimentation au gaz naturel Pour effectuer la conversion pour une alimentation au p...

Page 14: ... La canalisation doit se trouver en un endroit facilement accessible pour les manœuvres d ouverture fermeture Ne pas entraver l accès au robinet d arrêt manuel Le robinet d arrêt manuel est prévu pour ouvrir ou fermer l alimentation en gaz de la table de cuisson Régulateur de pression de gaz Le régulateur de pression de gaz fourni avec cette table de cuisson doit être utilisé La pression d aliment...

Page 15: ...n aux extrémités de la boîte des brûleurs Il s agit de l emplacement recommandé Des brides de fixation peuvent être installées à l avant et à l arrière de la partie inférieure de la boîte de brûleur si nécessaire 2 Les brides de fixation peuvent être installées avant ou après le positionnement de la table de cuisson dans l ouverture Procéder aux étapes suivantes pour l option choisie Installation ...

Page 16: ...liser une combinaison de raccords de tuyauterie pour raccorder la table de cuisson à l alimentation en gaz existante On voit ci dessous une illustration d un raccordement typique Le raccordement peut varier selon le type d alimentation la dimension et l emplacement 3 Orienter la flèche du détendeur vers le haut vers le fond de la boîte des brûleurs et orienter horizontalement le détendeur de telle...

Page 17: ...uton de commande d un brûleur de la table de cuisson à la position LITE allumage le système génère des étincelles pour l allumage du brûleur La génération d étincelles se poursuit aussi longtemps que le bouton de commande est laissé à la position LITE Contrôle du fonctionnement des brûleurs de surface Enfoncer et tourner les boutons de commande des brûleurs de surface à la position LITE Le gaz doi...

Page 18: ...inimum on doit observer des flammes stables bleues de 0 64 cm S il est nécessaire de régler la taille des flammes pour le débit thermique minimum La vis de réglage au centre de la tige de commande du robinet permet de régler la taille des flammes La tige de commande est située directement au dessous du bouton de commande 1 Ôter le bouton de commande 2 Immobiliser la tige de commande avec une pince...

Page 19: ...20 A COMMUTATEURS DE SOUPAPES ÉLECTRODES D ALLUMAGE BROCHE D ALIMENTATION DE 1 4 PO DE LARGE BROCHE RONDE DE MISE À LA TERRE TERMINAUX DE CONNECTION 0 250 CIRCUIT ÉLECTRIQUE FERMÉ LORSQUE LE BOUTON EST TOURNÉ DE 55 À 95 DANS LE SENS ANTI HORAIRE À PARTIR DE OFF COMMUTATEURS SUR SOUPAPES BROCHE NEUTRE 5 16 PO DE LARGE VE OU VE JA 5 JA OU MAR 5 PLCS 4 3 2 1 N L1 BL N N N FICHE TERRE TERRE TERRE MODU...

Page 20: ...8286304 2005 Whirlpool Corporation All rights reserved Tous droits réservés 4 05 Printed in U S A Imprimé aux É U ...