background image

30" Freestanding and Slide-In Dual Fuel Range

®

PRODUCT MODEL NUMBERS

PRODUCT DIMENSIONS

KDRS807S

KDSS907S

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

The cooktop sides of the slide-in range fit over the
cutout edge of your countertop.

If you have a square finish (flat) countertop and the
opening width is 30" (76.2 cm), no countertop
preparation is required.

Formed front-edged countertops must have molded
edge shaved flat 3/8" (1.0 cm) from each front corner
of opening.

Tile countertops may need trim cut back 
3/8" (1.0 cm) from each front corner and/or rounded
edge flattened.

If countertop opening width is greater than 
30" (76.2 cm), adjust the 3/8" (1.0 cm) dimension.

Countertop must be level. Place level on countertop,
first side to side; then front to back. If countertop is
not level, range will not be level. Range must be level
for satisfactory baking conditions.

Gas supply:

Provide a gas supply line of 3/4" 

(1.9 cm) rigid pipe to the range location. A smaller
size pipe on longer runs may result in insufficient
gas supply. Pipe-joint compounds that resist the
action of LP gas must be used. Do not use
TEFLON

®

tape. With LP gas, piping or tubing size

can be 1/2" (1.3 cm) minimum. Usually, LP gas
suppliers determine the size and materials used in
the system. If local codes permit, a new CSA
design-certified, 4' - 5' (122 - 152.4 cm) long, 
1/2" (1.3 cm) or 3/4" (1.9 cm) I.D., flexible metal
appliance connector may be used for connecting
range to the gas supply line. A 1/2" (1.3 cm) male
pipe thread is needed for connection to the female
pipe threads of the inlet to the appliance pressure
regulator. The supply line must be equipped with a
manual shutoff valve. This valve should be located
in the same room but external to the range. It
should be in a location that allows ease of opening
and closing.

Electrical:

When a 4-wire or 3-wire, single phase

120/240 volt, 60 Hz, AC only electrical supply is
available, a 50-amp maximum circuit protection is
required. When a 4-wire or 3-wire single phase
120/208 volt 60 Hz, AC only electrical supply is
available, a 40-amp maximum circuit protection is
required, fused on both sides of the line. A separate
circuit is recommended. A time-delay fuse or circuit
breaker is recommended.

Ref. W10154991

06-24-08

Freestanding Range

Slide-in Range

  

  

  

30"

(76.2 cm)

30"

(76.2 cm)

30-9/16"

(77.6 cm)

5-3/4"

(14.6 cm)

36" (91.4 cm)
cooktop trim
hei

g

ht with

levelin

g

 le

g

s

screwed all
the way in*

35-5/8" (90.5 cm)
hei

g

ht to underside

of cooktop ed

g

e

with levelin

g

 le

g

s

screwed all 
the way in*

41-3/4" 

(106 cm)

overall hei

g

ht 

with levelin

g

 

le

g

s screwed 

all the way in*

Model/serial number
plate (located on the

ri

g

ht-hand side

oven door trim)

27-1/4" 

(69.2 cm) max.

from handle to 

standoff at 

back of ran

g

e**

27-1/4" 

(69.2 cm) max.

from handle to 

standoff at 

back of ran

g

e**

23" (58.4 cm)

countertop

notch to rear

of countertop

Model/serial 

number plate 

(located on the

ri

g

ht-hand side

oven door trim)

30"

(76.2 cm)

30 ¾"

(78.1 cm)

³⁄₈

"

(1.0 cm)

*Range can be raised approximately 1" 

(2.5 cm) by adjusting the leveling legs.

**When installed in a 24" (61 cm) base cabinet

with 25" (63.5 cm) countertop; front of oven
door protrudes 1" (2.5 cm) beyond 24" 
(61 cm) base cabinet.

*Range can be raised approximately 1" 

(2.5 cm) by adjusting the leveling legs.

**When installed in a 24" (61 cm) base cabinet

with 25" (63.5 cm) countertop; front of oven
door protrudes 1-3/4" (4.4 cm) beyond 
24" (61 cm) base cabinet.

SLIDE-IN COUNTERTOP PREPARATION

INSTALLATION CLEARANCES

18" (45.7 cm)

upper cabinet
to countertop

18" (45.7 cm)

upper cabinet
to countertop

13" (33 cm) upper

cabinet depth

13" (33 cm) max.

upper cabinet depth

30" (76.2 cm) min.

openin

g

 width

30" (76.2 cm) min.

openin

g

 width

For minimum

clearance to top

of the cooktop,

see NOTE.

For minimum

clearance to top

of the cooktop,

see NOTE.

30" (76.2 cm)
min. openin

g

width

30" (76.2 cm)
min. openin

g

width

This shaded area

recommended for

installation of

ri

g

id 

g

as pipe.

This shaded area

recommended 
for installation 

of outlet or 

junction box.

This shaded area

recommended 
for installation 

of outlet or 

junction box.

Available 

area for 

g

as and 

electric

installation.

8" 

(20.3 cm)

6" 

(15.2 cm)

6" 

(15.2 cm)

8" 

(20.3 cm)

7" (17.8 cm)

7" (17.8 cm)

1-1/2" 

(3.8 cm)

1-1/2" 

(3.8 cm)

4-1/2" 

(11.4 cm)

4-1/2" 

(11.4 cm)

4-1/2" 

(11.4 cm)

4-1/2" 

(11.4 cm)

5" (12.7 cm) min.

clearance from

both sides of the
ran

g

e to the side

wall or other
combustible

material. 

5" (12.7 cm) min.

clearance from

both sides of the
ran

g

e to the side

wall or other
combustible

material. 

Cabinet door

or hin

g

e

should not

extend into

the cutout.

Cabinet door

or hin

g

e

should not

extend into

the cutout.

3/4" (1.9 cm) 

radius both corners

22-15/16" (58.3 cm)

openin

g

 depth

This shaded area

recommended for

installation of

ri

g

id 

g

as pipe.

Available 

area for 

g

as and 

electric

installation.

s

e

g

n

a

R

 

n

I

-

e

d

i

l

S

s

e

g

n

a

R

 

g

n

i

d

n

a

t

s

e

e

r

F

NOTE:

24" (61 cm) minimum when bottom of
wood or metal cabinet is protected by
not less than 1/4" (0.64 cm) flame
retardant millboard covered with not
less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 
0.024" (0.6 mm) aluminum or 0.020"
(0.5 mm) copper. 

30" (76.2 cm) minimum clearance
between the top of the cooking
platform and the bottom of an
unprotected wood or metal cabinet.

If installing a range hood or
microwave hood combination above
the range, follow the range hood or
microwave hood combination
installation instructions for
dimensional clearances above the
cooktop surface.

Reviews: