16
To adjust standard burners:
The flame can be adjusted using the adjustment screw in the
center of the valve stem. The valve stem is located directly
underneath the control knob.
If the low flame needs to be adjusted:
1.
Light one burner and turn to lowest setting.
2.
Remove the control knob.
3.
Hold the knob stem in the low position using a pair of pliers.
Use an 1/8" (3.0 mm) flat-blade screwdriver to turn the screw
located in the center of the control knob stem until the flame is
the proper size.
4.
Replace the control knob.
5.
Test the flame by turning the control from Low to High,
checking the flame at each setting.
6.
Repeat above steps for each burner.
Power failure
In case of prolonged power failure, the surface burners can be lit
manually. Hold a lit match near a burner and turn knob
counterclockwise to the Ignite position. After burner lights, turn
knob to setting. The vent fan will not work.
NOTE:
The downdraft vent will not operate during a power failure.
Complete Installation
1.
Check that all parts are now installed. If there is an extra part,
go back through the steps to see which step was skipped.
2.
Check that you have all your tools.
3.
Dispose of/recycle all packaging materials.
4.
Use a mild solution of liquid household cleaner and warm
water to clean cooktop before use. Dry thoroughly with a soft
cloth. For more information, see the “Cooktop Maintenance
and Care” section.
5.
Read the Quick Start Guide and online Control Guide
6.
Reconnect power.
If you need Assistance or Service: