6
Location Requirements
Select a location that provides minimum exposure to wind and
traffic paths. The location should be away from strong draft
areas.
Do not obstruct flow of combustion and ventilation air.
Clearance to combustible construction for built-in outdoor sear
burners:
■
A minimum of 24" (58 cm) must be maintained between the
sides and back and any combustible construction.
■
A zero clearance may be maintained below the cooking
surface and any combustible construction.
Ignition
A grounded, 3-prong outdoor GFI outlet is to be located inside
the island cabinet and to the left of the sear burner is required.
See “Electrical Requirements” section.
Product Dimensions
Built-In Outdoor Sear Burner Enclosure
This built-in outdoor sear burner is for installation in a built-in
enclosure constructed of combustible and non-combustible
materials. Some types of non-combustible materials could be
brick, firewall or steel. Some types of combustible materials
could be wood or laminate.
The enclosure for the built-in outdoor sear burner is to be a
minimum of 11" (28.0 cm) high x 23" (58.4 cm) deep x
14" (35.6 cm) wide.
Cabinet Dimensions
Counter or support surfaces must be level.
The installation of this sear burner must conform with local codes
or, in the absence of local codes, with either the National Fuel
Gas Code, ANSI Z223.1/NPFA 54, Natural Gas and Propane
Installation Code, CSA B149.1, or Propane Storage and Handling
Code, B149.2.
Copies of the standards listed may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
NOTE: The outdoor sear burner drops into the enclosure opening
and is supported by its side flanges. No bottom support is
needed.
A. 13" (33.0 cm)
B. 10
⁵⁄₈
" (27.0 cm)
C. 17" (43.2 cm)
D. 26
³⁄₈
" (67.0 cm)
E. 25
³⁄₈
" (64.5 cm)
F. Manifold pipe
G. 2
¹⁄₂
" (6.4 cm)
H. 22
³⁄₄
" (57.8 cm)
B
A
D
E
F
G
H
B
C
Summary of Contents for KBEU121TSS
Page 26: ...26 Notes ...