4-
14.
To remove the magnetron:
a) Discharge the high voltage capacitor
by touching the leads of a 20,000
Ω
re-
sistor from each of the capacitor leads
to the chassis ground.
b) Remove the mounting bracket and cav-
ity thermostat #1 (see page 4-12 for the
procedure).
c) Remove the magnetron thermostat from
the magnetron (see page 4-18 for the
procedure).
d) Disconnect the filament wire connec-
tors from the magnetron terminals.
e) Remove the four screws from the mag-
netron and remove the magnetron from
the oven.
c) Disconnect the wire connectors from
the high-voltage capacitor terminals.
d) Loosen the bracket screw, slide the high-
voltage capacitor out of the bracket, and
remove the capacitor.
High-Voltage
Capacitor Wires
2 Red
1 White
Bracket Screw
High-Voltage Capacitor
Filament Wires
4 Magnetron Screws
Summary of Contents for KAC-48