3. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
4. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
5. Remove cooktop burner caps and grates from parts
package. Align notches in burner caps with pins in burner
base. Burner caps should be level when properly positioned.
If burner caps are not properly positioned, surface burners
will not light.
6. Place burner grates over burners and caps as shown in the
following illustration. When properly installed the grates
should not overlap the console.
Freestanding Models
Slide-In Models
7. Plug into a grounded 3 prong outlet.
Electronic Ignition System
Initial lighting and gas flame adjustments
Cooktop and oven burners use electronic igniters in place of
standing pilots. When the cooktop control knob is turned to the
“LITE” position, the system creates a spark to light the burner.
This sparking continues as long as the control knob is turned to
“LITE.”
When the oven control is turned to the desired setting, sparking
occurs and ignites the gas.
Check Operation of Cooktop Burners
Standard Surface Burners
Push in and turn each control knob to the “LITE” position.
The flame should light within 4 seconds. The first time a burner is
lit, it may take longer than 4 seconds to light because of air in the
gas line.
TripleTier
®
Flame Burner
To start simmer burner:
Push in and turn control knob to “LITE” to start the inner burner.
The flame should light within 4 seconds. The first time a burner is
lit, it may take longer than 4 seconds to light because of air in the
gas line.
To start power burner:
Push in control knob again and turn to “POWER BURNER HI”
(turn control knob to DUAL HI on model KGSS907XSP) to light
the outer burner.
The flame should light within 4 seconds. The first time a burner is
lit, it may take longer than 4 seconds to light because of air in the
gas line.
If burners do not light properly:
■
Turn cooktop control knob to the “OFF” position.
■
Check that the range is plugged in and the circuit breaker has
not tripped or the household fuse has not blown.
■
Check that the gas shutoff valves are set to the “open”
position.
■
Check that burner caps are properly positioned on burner
bases.
Repeat start-up. If a burner does not light at this point, turn the
control knobs to “Off” and contact your dealer or authorized
service company for assistance.
A. Closed valve
B. Open valve
A. Burner base
B. Burner cap
C. Burner grate
A. Opening in grate for wok insert to be
located over left front burner
A. Large flange with rounded corner must be
at rear corner of the cooktop.
A
B
A
B
C
A
A
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
Summary of Contents for Architect KGSS907XSP
Page 21: ...21 Notes ...