Electrical Requirements - U.S.A. Only

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes and that the ground path is adequate.

Check with a qualified electrical installer if you are not sure the 
range is properly grounded.

Do not use an extension cord.

Make sure that the electrical connection and wire size are 
adequate and in conformance with the National Electrical Code, 
ANSI/NFPA 70-latest edition and all local codes and ordinances.

A copy of the above code standards can be obtained from:

National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269

Electrical Connection

To properly install your range, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.

Range must be connected to the proper electrical voltage 
and frequency as specified on the model/serial number rating 
plate. (The model/serial number rating plate is located on the 
right vertical surface of the oven door frame.)

Range must be connected to a grounded metal, permanent 
wiring system.

A 4-wire or 3-wire, single phase, 120/240 volt, 60 Hz., AC 
only electrical supply is required on a separate, 30-amp 
circuit, fused on both sides of the line. 

A time-delay fuse or circuit breaker is recommended. The 
fuse size must not exceed the circuit rating of the range 
specified on the model/serial rating plate located on the right 
vertical surface of the oven door frame. Refer to the figure in 
the “Product Dimensions” section of “Location 
Requirements” section.

The range can be connected directly to the fused disconnect 
(or circuit breaker box) through flexible, or nonmetallic 
sheathed, copper or aluminum cable. The flexible, cable 
extending from the fuse box or circuit breaker box should be 
connected directly to the junction box. See “Make Electrical 
Connection.”

Locate the junction box to allow as much slack as possible 
between the junction box and the range so that the range can 
be moved if servicing is ever necessary. Do not cut the 
conduit.

A UL listed or CSA approved conduit connector must be 
provided at each end of the power supply cable (at the range 
and at the junction box).

Wire sizes and connections must conform with the rating of 
the range (30 amps).

If the house has aluminum wiring follow the procedure below:

1. Connect a section of solid copper wire to the pigtail 

leads.

2. Connect the aluminum wiring to the added section of 

copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.

Electrical Requirements - Canada Only

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.

Be sure that the electrical connection and wire size are adequate 
and in conformance with the CSA Standard C22.1, Canadian 
Electrical Code, Part 1 - latest edition, and all local codes and 
ordinances.

A copy of the above code standards can be obtained from:

Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA.

Check with a qualified electrical installer if you are not sure 
the range is properly grounded.

When a 4-wire, single phase 208/240 volt, 60 Hz., AC only 
electrical supply is available, a 30-amp minimum circuit 
protection is required, fused on both sides of the line.

A time-delay fuse or circuit breaker is recommended.

This range is equipped with a CSA International Certified 
Power Cord intended to be plugged into a standard 14-50R 
wall receptacle. Be sure the wall receptacle is within reach of 
range’s final location.

Do not use an extension cord.

WARNING

Electrical Shock Hazard

Electrically ground range.

Failure to do so can result in death, fire, or 
electrical shock.

Summary of Contents for 9760618

Page 1: ...OFF F F O O F FF F O OFF F F O O F FF F O OFF F F O OFF F F O OFF F O OFF F O IMPORTANT Save for local electrical inspector s use Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future reference IMPORTANT À conserver pour consultation par l inspecteur local des installations électriques Installateur Remettre les instructions d installation ...

Page 2: ...lation de la bride antibasculement 22 Fixation du dosseret ou de la garniture en îlot 22 Raccordement à la canalisation de gaz 23 Système d allumage électronique 24 Réinstallation de l évent du fond 25 Achever l installation 25 SCHÉMAS DE CÂBLAGE 26 RANGE SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety mes...

Page 3: ...r WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions In the State of Massachusetts the following installation instructions apply Installations and repairs must be performed by a qualified or licensed...

Page 4: ... codes and ordinances Do not obstruct flow of combustion and ventilation air It is the installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located on the right vertical surface of the oven door frame It is recommended that a 600 CFM range hood be installed above the range Recessed installations must provide c...

Page 5: ...8 cm beyond 24 61 cm base cabinet Cabinet Dimensions Cabinet opening dimensions shown are for 25 64 cm countertop depth 24 61 cm base cabinet depth and 36 91 4 cm countertop height IMPORTANT If installing a range hood above the range follow the range hood instructions for dimensional clearances above the cooktop surface NOTE Receptacle must be rotated 90 for Canadian installation NOTE 42 106 7 cm ...

Page 6: ...box See Make Electrical Connection Locate the junction box to allow as much slack as possible between the junction box and the range so that the range can be moved if servicing is ever necessary Do not cut the conduit A UL listed or CSA approved conduit connector must be provided at each end of the power supply cable at the range and at the junction box Wire sizes and connections must conform with...

Page 7: ... must be used Do not use TEFLON tape With LP gas piping or tubing size can be 1 3 cm minimum Usually LP gas suppliers determine the size and materials used in the system Flexible metal appliance connector If local codes permit a new CSA design certified 4 5 ft 122 152 4 cm long 1 6 cm or 1 9 cm I D flexible metal appliance connector may be used for connecting range to the gas supply line A 1 3 cm ...

Page 8: ...g its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 5 kPa INSTALLATION INSTRUCTIONS UnpackRange 1 Remove shipping materials tape and film from range Keep shipping pallet under range Remove oven racks grates and parts package from inside oven 2 Remove the 2 screws on each side of the top of the bottom vent S...

Page 9: ...e This range is manufactured with a cabinet connected green or bare ground wire Connect the range cable to the junction box through the UL listed or CSA approved conduit connector 1 Disconnect power 2 Remove junction box cover if present 3 Install a UL listed or CSA approved conduit connector to the junction box 4 Route the flexible cable conduit from the range to the junction box using a UL liste...

Page 10: ...t opening 2 Remove cardboard or hardboard from under range Move range into its final location 3 Attach the backguard or island trim as required for your installation See Tools and Parts Attachment screws are included in the package containing literature Attaching the Backguard Attaching the Island Trim 4 Using 2 or more people tip the range back so that the front feet lift off the ground Slide ran...

Page 11: ...lay For further information please refer to the user instructions located in the Use and Care Guide ElectronicIgnitionSystem Initial lighting and gas flame adjustments Cooktop and oven burners use electronic igniters in place of standing pilots When the cooktop control knob is turned to the LITE position the system creates a spark to light the burner This sparking continues as long as the control ...

Page 12: ... and hold hand above oven floor and feel for heat Do not touch oven floor Press CANCEL and turn oven selector to RESET Check Operation of Oven Broil Element 1 Close the oven door 2 Turn oven selector to BROIL HI will appear in the temperature display 3 Press ENTER Look through oven window The top element should glow red and heat should be radiating out of the door Press CANCEL and turn oven select...

Page 13: ...g material Dry thoroughly with a soft cloth For more information see the Range Care section of the Use and Care Guide 9 Read Range Use in the Use and Care Guide 10 Turn on surface burners and oven See the Use and Care Guide for specific instruction on range operation If range does not operate check the following Household fuse has not blown or circuit breaker has not tripped Gas valves are turned ...

Page 14: ...14 Oven Schematic Blower remains off until oven reaches 190 F 88 C and may continue running up to 45 minutes after oven has turned off NOTE Circuit is shown in standby off mode with oven door closed ...

Page 15: ...15 Notes ...

Page 16: ...VERTISSEMENT Si les renseignements dans ce manuel ne sont pas exactement observés un incendie ou une explosion peut survenir causant des dommages au produit des blessures ou un décès Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d all...

Page 17: ...n Vérifier les codes locaux et consulter le fournisseur de gaz Vérifier l alimentation en gaz et l alimentation électrique existantes Voir les sections Spécifications électriques et Spécifications de l alimentation en gaz Toutes les connexions électriques doivent être effectuées par un électricien qualifié et certifié Dans l État du Massachusetts les instructions d installation suivantes sont appl...

Page 18: ...sous la cuisinière une plaque d appui isolée ou une plaque de contreplaqué de 0 64 cm IMPORTANT Pour éviter tout dommage consulter le constructeur ou le fabricant du placard pour déterminer si les matériaux utilisés ne subiront pas un changement de couleur une déstratification ou d autres dommages Ce four a été conçu conformément aux exigences UL et aux normes de la CSA International il respecte l...

Page 19: ... canadien de l électricité et de tout code ou règlement local en vigueur On peut obtenir un exemplaire de la norme ci dessus auprès de Canadian Standards Association 178 Rexdale Blvd Toronto ON M9W 1R3 CANADA En cas de doute quant à la qualité de la liaison à la terre de la cuisinière consulter un électricien qualifié Lorsqu une source d électricité monophasée de 208 240 volts 60 Hz 4 conducteurs ...

Page 20: ...s En général le fournisseur de gaz propane détermine les matériaux à utiliser et le diamètre approprié Raccord métallique flexible Si le code local le permet on peut utiliser pour raccorder la cuisinière à la canalisation de gaz un raccord métallique flexible neuf homologation CSA de 4 5 pi 122 152 4 cm de longueur de diamètre interne de 1 6 cm ou 1 9 cm Un raccord avec filetage mâle de 1 3 cm est...

Page 21: ...n robinet d arrêt manuel individuel INSTRUCTIONS D INSTALLATION Déballagedelacuisinière 1 Ôter les matériaux d emballage le ruban adhésif et le film protecteur de la cuisinière Maintenir la palette d expédition sous la cuisinière Retirer les grilles de four et le sachet de pièces de l intérieur du four 2 Ôter les 2 vis de chaque côté de la partie supérieure de l évent du fond Faire glisser l évent...

Page 22: ... longues peuvent être nécessaires Des vis plus longues sont disponibles auprès de votre quincaillerie locale Fixationdudosseretoudelagarnitureenîlot 1 À deux personnes ou plus déplacer la cuisinière près de l ouverture d encastrement 2 Retirer le carton ou le panneau de fibre dur de sous la cuisinière Déplacer la cuisinière à son emplacement final 3 Fixer le dosseret ou la garniture en îlot en fon...

Page 23: ...êt manuel sur la canalisation de gaz la manette doit être parallèle au tuyau 2 Effectuer une recherche des fuites appliquer au pinceau sur les connexions une solution non corrosive de détection des fuites la formation de bulles identifiera une fuite Éliminer toute fuite constatée 3 Prendre les chapeaux de brûleur les grilles de brûleur et la plaque de mijotage dans le paquet de pièces Aligner les ...

Page 24: ...ton de commande 2 Immobiliser la tige de commande avec une pince Utiliser un petit tournevis à lame plate pour faire tourner la vis située au centre de la tige de commande ajuster les flammes à la taille désirée 3 Réinstaller le bouton de commande 4 Tester le fonctionnement du brûleur faire passer le bouton de commande de la position LO bas à la position HI élevé et observer les flammes pour chaqu...

Page 25: ...rizontal jusqu aux matériaux combustibles derrière la surface de cuisson est inférieur à 1 2 5 cm 7 Vérifier que la cuisinière est raccordée uniquement au type de gaz pour lequel le fonctionnement est agréé 8 Utiliser une solution d eau tiède et de nettoyant ménager doux pour éliminer tout résidu de cire laissé par les matériaux de protection de l emballage Sécher parfaitement avec un linge doux P...

Page 26: ...ebranchement pourrait provoquer un fonctionnement incorrect et une situation dangereuse Le cordon d alimentation sur cet appareil est équipé d une fiche à 3 alvéoles reliée à la terre qui s adapte à toute prise standard à 3 alvéoles reliée à la terre Vérifier le bon fonctionnement de l appareil après l intervention Schéma de câblage de la table de cuisson ...

Page 27: ...r Le ventilateur reste éteint jusqu à ce que le four atteigne 190 F 88 C et peut continuer de fonctionner jusqu à 45 minutes après que le four est éteint REMARQUE Circuit illustré en mode d attente arrêt avec porte du four fermée ...

Page 28: ... réservés Registered Trademark TM Trademark of KitchenAid U S A KitchenAid Canada licensee in Canada Marque déposée TM Marque de commerce de KitchenAid U S A Emploi sous licence par KitchenAid Canada au Canada 6 08 Printed in U S A Imprimé aux É U ...

Reviews: