Change Grill Main Burner Valve Orifices
3. Use a 6 mm socket and wrench or 6 mm nut driver to remove
the brass orifice from the end of gas valve. The main burner
orifice is located behind the LP orifice, so no additional orifice
needs to be installed.
A. Main burner orifice
IMPORTANT:
Check that the orifice is properly installed inside of the
burner opening.
4. Reinsert the burner and reattach using the screw and cotter clip
previously removed. Repeat the procedure for each main burner.
5. Position the igniters so they are 1/4" (6.0 mm) away from each
burner.
1. Remove the grates and flame tamers.
2. Remove 1 screw and cotter clip that hold the burner in place. Set
the screw and clip aside. Remove the burner from the grill by lifting
the burner out.
Change the Sear Burner Orifices
1. Remove the 2 screws securing the igniter and remove
the igniter from the side burner.
2. Remove the searing side burner screws. Set the screws
and cover aside.
18
A
B
A. Screw
B. Cotter Clip
orifice
orifice
A