4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.
Tools needed
■
Level
■
Drill
■
1¹⁄₄
" (3.0 cm) drill bit
■
Pilot hole drill bits (determined by chimney support
attachment method)
■
³⁄₁₆
" (5 mm) drill bit if installing in-line blower motor system
■
Pencil
■
Wire stripper or utility knife
■
Tape measure or ruler
■
Pliers
■
Caulking gun and weatherproof caulking compound
■
Jigsaw or keyhole saw
■
Flat-blade screwdriver
■
Phillips screwdriver
■
Vent clamps
■
Metal snips
Parts needed
■
1 UL listed or CSA approved,
¹⁄₂
" (12.5 mm) strain relief
■
3 UL listed wire connectors
■
Home power supply cable
■
4 Concrete anchors for
¹⁄₄
" x 4" hex head lag bolts
(for concrete installation)
■
1 Wall or roof cap
■
Metal vent system
■
Blower motor system - internal or external (See “Blower
Motor System” in the “Accessories” section.)
Parts supplied
Remove parts from packages. Check that all parts were included.
■
Hood canopy assembly with ventilator and light bulbs
installed
■
2 Grease Filters for 36" (91.4 cm) models
3 Grease Filters for 48" (121.9 cm) models
■
Mounting template
■
2 Support brackets
■
8 Vertical supports
■
2 Vent cover supports
■
2 Upper chimney covers
■
2 Lower chimney covers (front and rear)
■
Upper horizontal support bracket
■
Horizontal support
■
4 - 5 x 45 mm mounting screws
■
72 - 4.2 x 8 mm mounting screws
■
T-20 TORX
®†
adapter
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial rating plate. The model/serial rating
plate is located inside the range hood on the rear wall of the
range hood.
Island hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
It is recommended that the hood be fastened into solid wood.
The island hood is factory set for venting through the roof or
through the wall.
All openings in ceiling and where island hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local
codes.
Product Dimensions
Vented Installations
†®TORX is a registered trademark of Saturn Fasteners, Inc.
12
¹³⁄₁₆
" (32.6 cm)
23
¹⁵⁄₁₆
"
(60.8 cm
)
36" (91.4 cm) or
48" (121.9 cm)
27
⁹⁄₁₆
" (70.0 cm)
44¹⁵⁄₁₆
" (114.1 cm) max.
31
¹⁄₂
" (80 cm) min.
19" (48.2 cm)