KisanKraft
®
AGRICULTURAL INTER-CULTIVATOR
KK-IC-400D
: +91.80. 22178200
Page 30 of 56
Cause
Remedy
A.
Failure of fuel system
1.
Air mixing in fuel system
Evacuate the air
2.
Bad fuel quality or water
mixing in fuel
Check the fuel and replace it if necessary
3.
Injector parts are jammed or
excessive injection pressure
Check injector and adjust injection pressure
4.
Needle valve parts of injector
is worn out or parts are
blocked by injector stem
Check the parts and replace if necessary.
B.
Speed regulating system is seized
Check, repair or replace the regulating valve.
Self-Shutdown of Diesel Engine:
Cause
Remedy
A.
Failure of fuel system
1.
Insufficient fuel in oil tank
Refill the fuel
2.
Diesel oil filter and oil supply duct
are blocked or gas leakage
Clean or evacuate the air
3.
Injector parts are seized
Clean or grind parts and replace if
necessary
B.
Failure of lubrication system
1.
Insufficient engine oil in crank
case causes damages of
mechanical parts
Fill engine oil, repair damaged parts and
replace if necessary
2.
Bad lubrication of crank journal
damages the bushing
Clean oil passage, repair damaged parts
Other Failures:
Cause
Remedy
A.
Injector is seized often
1.
High temperature crash stop
Crash stop is not allowed.
2.
Unclean fuel or damaged fuel
filter.
Clean oil tank, replace fuel filer
B.
Engine oil overflows from exhaust
1.
Piston or cylinder head is worn
out
Check, repair and replace the piston or
cylinder if necessary
2.
Throttle duct is worn out
Check, repair and replace the throttle duct
if necessary.
3.
Piston ring is bonded or
damaged
Clean or replace the piston ring