IMPORTANT SAFETY INFORMATION 

This  section  contains  important  safety  information  for  the 

KISAE  Abso  DC  to  DC  Battery 

Charger

. Each time, before using the unit, READ ALL instructions and cautionary markings on or 

provided  with  the  unit,  and  all  appropriate  sections  of  this  guide.  The  unit  contains  no  user-
serviceable parts. See Warranty section for how to handle product issues. 

 

 

WARNING: Fire and/or Chemical Burn Hazard!  

  Do not cover or obstruct any air vent openings and/or install in a zero-clearance compartment.  

 
WARNING: Failure to follow these instructions can result in death or serious injury. Keep away 

from children!

 

  When working with electrical equipment or lead acid batteries, have someone nearby in case of an 

emergency. 

 

Study  and  follow  all  the  battery  manufacturer’s  specific  precautions  when  installing,  using  and 
servicing the battery connected to the charger.  

  Wear eye protection and gloves. 

  Avoid touching your eyes while using this unit. 

  Keep  fresh  water  and  soap  on  hand  in  the  event  battery  acid  comes  in  contact  with  eyes.  If  this 

occurs,  cleanse  right  away  with  soap  and  water  for  a  minimum  of  15  minutes  and  seek  medical 
attention. 

  Batteries produce explosive gases. 

DO NOT 

smoke or have an open spark or fire near the system. 

  Keep unit away from moist or damp areas. Never expose unit to snow, water etc. 

  Avoid dropping any metal tool or object on the battery. Doing so could create a spark or short circuit 

which goes through the battery or another electrical tool that may create an explosion. 

 
WARNING: Explosion hazard!

 

  Do  not  use  the  unit  in  the  vicinity  of  flammable  fumes  or  gases  (such  as  propane  tanks  or  large 

engines). 

  Avoid covering the ventilation openings. Always operate unit in an open area. 

  Prolonged contact to high heat or freezing temperatures will decrease the working life of the unit. 

  The 

DMT2430

 unit is designed for use on 

24V  House  Battery  System

 only. Do not use it on 12V 

House Battery System. 

 
CAUTION:

 

  This  appliance  is  not  intended  for  use  by  persons  (including  children)  with  reduced  physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliance by a person responsible for their safety. 

  Children should be supervised to ensure that they do not play with the appliance. 

  Do not charge non-rechargeable batteries because of the danger of eruption. 

  During charging, batteries should be placed in a ventilated area. 

  The battery terminal not connected to the chassis has to be connected first. 

  The  other  connection  is  to  be  made  to  the  chassis,  remote  from  the  battery  and  fuel  line.  The 

battery charger is then to be connected to the supply mains (household power). 

  After  charging,  disconnect  the  battery  charger  from  the  supply  mains.  Then  remove  the  chassis 

connection and then the battery connection. 

  Only allow children at least 8 years old to use the battery charger. Give sufficient instruction so that 

the child is able to use the battery charger in a safe way and explain that it is not a toy and must not 
be played with. 

  Examine  the  battery  charger  regularly  for  damage,  especially  the  cord,  plug  and  enclosure.  If  the 

battery charger is damaged, it must not be used until it has been repaired. 

 

Summary of Contents for DMT1230

Page 1: ...Abso DC to DC Battery Charger 12V 30A DMT1230 12V 50A DMT1250 24V 30A DMT2430 Owner s Manual...

Page 2: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may c...

Page 3: ...ents 1 INTRODUCTION 5 2 PRODUCT DESCRIPTION 5 3 UNDERSTANDING THE UNIT 5 4 INSTALLING THE CHARGER 8 5 CONNECTING THE CHARGER 8 6 UNIT OPERATION 10 7 SPECIFICATIONS 16 8 WARRANTY 17 Appendix A1 18 Appe...

Page 4: ...on WARNING Explosion hazard Do not use the unit in the vicinity of flammable fumes or gases such as propane tanks or large engines Avoid covering the ventilation openings Always operate unit in an ope...

Page 5: ...the input of multiple sources you can be assured of charging your batteries whenever underway or when the sun is shining on your solar array As dictated by battery manufacturer recommendations deep cy...

Page 6: ...er for equalization recommendations Bulk Absorption Absorption Float Stage Current Setting The Bulk Absorption Bulk Abs and Absorption Float Abs Float Stage current settings are based on the House Bat...

Page 7: ...the highest available current setting for battery protection Program Type House Battery Bank Voltage and Current Setting WARNING FIRE HAZARD When choosing the Program Battery type you can set to a wi...

Page 8: ...ertically Battery Terminals facing downwards to provide adequate drip protection Use the base of the charger as a mounting template to mark the positions of the fixing screws Drill the 4 fixing holes...

Page 9: ...e Battery bank Connect the CH1 terminal to the negative terminal of the House Battery Bank Make all the and wire connections on CH2 Solar Array Panel and CH3 Alternator Start battery See more details...

Page 10: ...eturns to 13 2V on a 12V Input system or 26 4V on a 24V Input system Note B When the unit has activated the battery charging process using the Control terminal or using the Manual Override through the...

Page 11: ...e i e 13 2V 12 3V on 12V CH3 battery system or 26 4 24 6V on 24V CH3 battery system under Normal Priority mode respectively and it is not the charging source of the House Battery bank yet It will chan...

Page 12: ...ven better a one indicating engine running to the Control terminal of the charger so to make sure that the Override Mode is activated only when the engine alternator is running This automatic setting...

Page 13: ...oltage is automatically adjusted as per the following table Measured Battery Temperature Automatic Battery Charging Voltage Adjustment from 25 C Flooded and GEL type AGM type 25 C 0 027V C 0 021V C 25...

Page 14: ...Please notice that using a jumper to connect the positive terminal of CH 1 and CH 2 will stop the control and regulation functions of the house battery Therefore keep this temporary bypass to increase...

Page 15: ...low 15 5V 31V respectively This may be due to charging from another charging source i e Another solar controller or AC battery charger with either an excessively higher voltage regulation setting or a...

Page 16: ...200 uA Battery Temperature Setting Low Normal High automatically overridden with optional BTS Efficiency 95 Minimum Operating Voltage 8 0 Vdc 16 0 Vdc DC Input Solar Array Panels CH2 Solar Input Volta...

Page 17: ...epresentative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufa...

Page 18: ...REV D Page 18...

Page 19: ...REV D Page 19...

Page 20: ...REV D Page 20...

Page 21: ...REV D Page 21...

Page 22: ...REV D Page 22...

Page 23: ...REV D Page 23...

Page 24: ...REV D Page 24 Printed in China...

Reviews: