Kisae DMT1230 Owner'S Manual Download Page 2

 

 

REV D

                                                                                                                                                                                                     Page 

2                          

 

 

 

For safe and optimum performance, the 

KISAE Abso DC to DC Battery Charger 

must be used properly. 

Carefully read and follow all instructions and guidelines in this manual and give special attention to the 

CAUTION

 and 

WARNING

 statements. 

PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE 

 

Disclaimer 

While every precaution has been taken to ensure the accuracy of the contents of this guide, 

KISAE 

Technology 

assumes no responsibility for errors or omissions. Note as well that specifications and 

product functionality may change without notice. 
 

Important  

Please  be  sure  to  read  and  save  the  entire  manual  before  using  your 

KISAE  DC  to  DC  Battery 

Charger. 

Misuse may result in damage to the unit and/or cause harm or serious injury.  

 
 

Product Numbers 

  DMT1230 

Abso DC to DC Battery Charger 12V 30A

 

  DMT1250 

Abso DC to DC Battery Charger 12V 50A 

  DMT2430 

Abso DC to DC Battery Charger 24V 30A 

 
Document Part Number 

 

  

MU DMT1230 Rev D 

 

 
Service Contact Information 

  Email:    [email protected] 
  Phone :   1 877 897-5778 
  Web : 

www.kisaepower.com

 

 
 

FCC and CE EMC INFORMATION  

This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  B  digital  device, 
pursuant  to  part  15  of  the  FCC  Rules  and  comply  with  the  limits  for  CE  EMC.  These  limits  are 
designed to provide reasonable protection against harmful interference in a residential installation. This 
equipment  generates  uses  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in 
accordance with the instructions, may cause harmful interference to radio communications. However, 
there is no guarantee that interference will not occur in a particular installation. If this equipment does 
cause  harmful  interference  to  radio  or  television  reception,  which  can  be  determined  by  turning  the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:  
•  Re-orient or re-locate the receiving antenna. 
•  Increase the separation between the equipment and the receiver.  
•  Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to  which  the  receiver  is 

connected.  

•  Consult the dealer or an experienced radio/TV technician for help.  

 
LIMITATIONS ON USE  

Do not use in connection with life support systems or other medical equipment or devices.  

 
 
 
 
 
 
 

WARNING: 

This product can expose you to chemicals, including Di (2-ethylhexyl) phthalate (DEHP)

 

which is known 

to the State of California to cause cancer, birth defects or other reproductive

 

harm. For more information, go to 

www.p65warnings.ca.gov

 

ADVERTENCIA 

Este producto puede exponerlo a químicos, incluyendo el ftalato de bis (2-etilhexilo) (DEHP) 

conocido por el estado de California como causante de cáncer, defectos de nacimiento, u otros daños 

reproductivos. Para obtener más información, entre a www.p65warnings.ca.gov

 

 

Summary of Contents for DMT1230

Page 1: ...Abso DC to DC Battery Charger 12V 30A DMT1230 12V 50A DMT1250 24V 30A DMT2430 Owner s Manual...

Page 2: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may c...

Page 3: ...ents 1 INTRODUCTION 5 2 PRODUCT DESCRIPTION 5 3 UNDERSTANDING THE UNIT 5 4 INSTALLING THE CHARGER 8 5 CONNECTING THE CHARGER 8 6 UNIT OPERATION 10 7 SPECIFICATIONS 16 8 WARRANTY 17 Appendix A1 18 Appe...

Page 4: ...on WARNING Explosion hazard Do not use the unit in the vicinity of flammable fumes or gases such as propane tanks or large engines Avoid covering the ventilation openings Always operate unit in an ope...

Page 5: ...the input of multiple sources you can be assured of charging your batteries whenever underway or when the sun is shining on your solar array As dictated by battery manufacturer recommendations deep cy...

Page 6: ...er for equalization recommendations Bulk Absorption Absorption Float Stage Current Setting The Bulk Absorption Bulk Abs and Absorption Float Abs Float Stage current settings are based on the House Bat...

Page 7: ...the highest available current setting for battery protection Program Type House Battery Bank Voltage and Current Setting WARNING FIRE HAZARD When choosing the Program Battery type you can set to a wi...

Page 8: ...ertically Battery Terminals facing downwards to provide adequate drip protection Use the base of the charger as a mounting template to mark the positions of the fixing screws Drill the 4 fixing holes...

Page 9: ...e Battery bank Connect the CH1 terminal to the negative terminal of the House Battery Bank Make all the and wire connections on CH2 Solar Array Panel and CH3 Alternator Start battery See more details...

Page 10: ...eturns to 13 2V on a 12V Input system or 26 4V on a 24V Input system Note B When the unit has activated the battery charging process using the Control terminal or using the Manual Override through the...

Page 11: ...e i e 13 2V 12 3V on 12V CH3 battery system or 26 4 24 6V on 24V CH3 battery system under Normal Priority mode respectively and it is not the charging source of the House Battery bank yet It will chan...

Page 12: ...ven better a one indicating engine running to the Control terminal of the charger so to make sure that the Override Mode is activated only when the engine alternator is running This automatic setting...

Page 13: ...oltage is automatically adjusted as per the following table Measured Battery Temperature Automatic Battery Charging Voltage Adjustment from 25 C Flooded and GEL type AGM type 25 C 0 027V C 0 021V C 25...

Page 14: ...Please notice that using a jumper to connect the positive terminal of CH 1 and CH 2 will stop the control and regulation functions of the house battery Therefore keep this temporary bypass to increase...

Page 15: ...low 15 5V 31V respectively This may be due to charging from another charging source i e Another solar controller or AC battery charger with either an excessively higher voltage regulation setting or a...

Page 16: ...200 uA Battery Temperature Setting Low Normal High automatically overridden with optional BTS Efficiency 95 Minimum Operating Voltage 8 0 Vdc 16 0 Vdc DC Input Solar Array Panels CH2 Solar Input Volta...

Page 17: ...epresentative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufa...

Page 18: ...REV D Page 18...

Page 19: ...REV D Page 19...

Page 20: ...REV D Page 20...

Page 21: ...REV D Page 21...

Page 22: ...REV D Page 22...

Page 23: ...REV D Page 23...

Page 24: ...REV D Page 24 Printed in China...

Reviews: