SPARE PARTS
A set of ball bearings, a set of casing rings must always be kept at hand to ensure uninterrupted
service from the pump while ordering for spare parts, always give type, size and serial number of
the pumps as stamped on the name plate.
14.
ENVIRONMENTAL ASPECTS:
Our products are designed and manufactured considering all environmental aspects to minimize impact
on the environment. We ensure that the product supplied by us utilizes less energy during their life
cycle and it does not emit any hazardous gas or cause any harm to any living being or to the
environment. User of this product is recommended to follow the operating instructions and maintain the
product in periodic manner, in order to ensure that it always functions with optimum energy efficiency.
Product Recycle Program
As a commitment towards a greener future, conservation of natural resources and reduction of carbon
foot print, Kirloskar Brothers Limited offers to take back/replace its used products once it has reached
the end-of-life and ensure that it is recycled/ disposed in an environment friendly manner with the
following objective.
MOTOR PROTECTION UNIT
MPU Will be supplied to suite the thermistor and moisture sensor in the pump. Vendor
can mount this unit on their local starter control panel.
Features of MPU:
• Protects pump motor against moisture in case of seal failure
• Protects pump motor winding by detecting High winding Temperature
• Din Rail Mounted compact unit can be placed in starter panel
• Easy Interfacing with starter panels
• LED indications for Moisture & High winding temperature.
Sr.
Particulars
Specifications
1
Enclosure
ABS
2
Mounting
Standard Din Rail
3
Terminations
Screw Type
4
Sensor Inputs
Moisture & PTC
5
Indications
LED, Moisture & High Winding
Temperature
6
Outputs
Potential Free Relays for Tripping,
Moisture & High
winding Temperature Faults
7
Main Supply
230 VAC, 50 Hz