GAS REQUIREMENTS & LEAK TESTING 

 

 

 

NEVER CONNECT AN UNREGULATED GAS SUPPLY TO THE HEATER 

PRECAUTIONS

z

 

Periodically check the whole gas system for 
leaks or immediately check if the smell of 
gas is detected 

z

 

Extinguish all open flames. 

z

 

Never leak test while smoking. 

z

 

If you cannot stop a leak, turn off the gas 
supply and call the Customer Service 
hotline, the dealer where you made the 
purchase or your gas supplier. 

z

 

The heater must be checked with a full 
cylinder. 

z

 

Do not use the heater until all connections   

have been leak tested and do not leak. 

z

 

Only those parts recommended by the 
manufacturer should be used. Substitution 
will void the warranty. 

 

GAS REQUIRMENTS 

z

 

Maximum inlet pressure to propane 
regulator must not exceed 100 PSI.   

z

 

A minimum supply pressure of 11.0 W.C. is 
required for the purpose of input adjustment 
for propane gas. 

z

 

The pressure regulator and hose assembly 
supplied with the appliance must be used. 
Replacement pressure regulator and hose 
must be specified by the appliance 
manufacturer. 

z

 

The installation must conform with local 
codes or in the absence of local codes, with 
National Fuel Gas Code, ANSI 
Z223.1-1996. 

z

 

The heater comes equipped with a hose 
assembly for hook-up to a standard                  

z

 

If a leak is present turn ‘OFF’ the gas supply, 
tighten any leaking fitting, turn gas supply ‘ON’   

z

 

A dented, rusted or damaged propane tank 
may be hazardous and should be checked by your 
tank supplier. Never use a propane tank with a 
damaged valve connection. 

z

 

The propane tank must be constructed and 

marked in accordance with the specifications for 
LP gas cylinders of the US Department Of 
Transportation (DOT) 

z

 

  The propane tank must be arranged to provide     

for vapor withdrawal from the operating   

cylinder 

z

 

Never connect an unregulated propane tank   

to the heater   

 
LEAK TESTING   

 

z

 

Gas connections on the heater are leak tested at 
the factory prior to shipment.    A complete gas 
tightness check must be performed at the 
installation on site due to possible miss handing 
in shipment or excessive pressure being applied 
to the heater.   

 
TO LEAK TEST   
 

z

 

Make a soap solution of one part liquid 
detergent and one part water. The solution can 
be applied with a spray bottle brush or rag. 
Soap bubbles will appear where a leak is present 

z

 

Make certain the safety control valve is in the 
‘OFF’ position 

z

 

Turn the gas supply ‘ON’. 

gas tank.    The propane tank is not included.        and recheck.  

 

propane   

Summary of Contents for PTH106SS-3G

Page 1: ...LIST 16 WARRANTY 17 READ THE FOLLOWING INSTRUCTIONS CAREFULLY AND BE SURE YOUR PATIO HEATER IS PROPERLY INSTALLED ASSEMBLIED AND CARED FOR FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN SERIOUS BO...

Page 2: ...an cause severe property damage or serious injury or death Please read the installation operation maintenance instructions thoroughly before installing or servicing this equipment FOR YOUR SAFETY If y...

Page 3: ...embly 1 LPG Gas regulator with Hose 1 Tank Hook 1 Hardware Bag Page2 Post Socket 1 4 Acorn cap 4 Post Socket 1 4 Flat Washer 4 Reflector 5 32 8mm Truss Head Screw 3 Reflector Plate 1 4 10mm Truss Head...

Page 4: ...damage the heater and render it unsafe for use Check the heater immediately if any of the following exists 1 The smell of gas in conjunction with extreme yellow tipping of the burner flames 2 The heat...

Page 5: ......

Page 6: ...TIONS Page4 STEP 1 Attach Table Legs z Attach the post socket to the top of the tank enclosure using four 1 4 flat washers and four 1 4 acorn caps z Secure the four table legs with four of 5 32 x 22mm...

Page 7: ...then tighten up with three 1 4 x 10mm truss head screws from the bottom up STEP 2 STEP 3 Attach The Reflector nut Post z Screw the 1 4 x2 3 4 1 4 x57mm dual threaded end stud into the emitter top z A...

Page 8: ...6 Page 6 STEP 4 Gas Tank z Open tank enclosure door z Secure the gas tank with the tank hook by attaching to the bracket of tank enclosure as show in diagram STEP 5 Attach Regulator z Attach flare ada...

Page 9: ...n must conform with local codes or in the absence of local codes with National Fuel Gas Code ANSI Z223 1 1996 z The heater comes equipped with a hose assembly for hook up to a standard z If a leak is...

Page 10: ...ch See diagram for Step 1 NOTE The remaining connections are to be tested after the heater has been lit STEP 2 4 Light the heater following instructions on page 10 and page 11 Page8 6 8 7 9 STEP 2 5 U...

Page 11: ...t be maintained at all times The installation must conform to local codes or in the absence of local codes with the standard for the storage and handling of liquid petroleum gases In the US use ANSI N...

Page 12: ...ounter clockwise direction Check for leaks by applying soapy water to the tank and hose connections D Push and turn the gas control knob to PILOT position The igniter will spark at the same time Firml...

Page 13: ...rid or reflector the heater should be turned off immediately and the heater should not be operated again until repairs are made FIGURE 2 NORMAL FLAME POSITION 2 50 8mm 1 25 4mm 0 0mm RELIGHTING A Turn...

Page 14: ...post base assembly Never paint the reflector emitter assembly the safety control valve cylinder valve panel or instruction plate on post The posts of the burner must remain clean so that the gas flow...

Page 15: ...er webs etc the pilot flame may be small and the thermocouple may not heat up enough for the main burner to come on If this occurs it will be necessary to clean the pilot Lower Cone Cylinder Safety Va...

Page 16: ...e pilot assembly to the lower screen cone 3 Hold the pilot assembly with slip joint pliers then loosen and remove the nut at the base of the pilot 4 Inspect the pilot and tubing for blockage You shoul...

Page 17: ...ouple connection loose at gas control or damaged Pilot flame not touching the thermocouple Low gas pressure Blockage in burner orifice Control knob not in ON position Purge gas line and repeat ignitio...

Page 18: ...er Grid Main Burner Assembly Emitter base Pilot Assembly Control Housing Front Panel Lighting Instruction Plate Valve Knob Control Housing Gas Valve Control Husing Base Post Square Table Post Socket P...

Page 19: ...s supply use contrary to operating instructions or alteration by any person other than our factory service center The warranty period is not extended by such repair or replacement Warranty claim proce...