Controls
4.6.8 Function 4-8: Simulation value temperatures
diagnosis
4-8
sim. values temp
Simulation of temperature values.
Code number to activate: user
Example:
sim. values temp
T1 = -5 1/10°C
Simulation value of temperature T1 = - 5°C
4.6.9 Function 4-9: Simulation temperatur on/off
diagnosis
4-9
simulate temp.
Switch the simulation of temperatures on and off.
This simulation is switched on only, if the temperature
measurement is activate in 5-1.
Code number to activate:
user
Example:
simulate temp.
active
Simulation of temperature on
4.6.10 Function 4-10: Check medium conductivity for medium detection
diagnosis
4-10
check medium
Identification of the actual conductivity of the medium
shown in %.
0% resp. 100% are minimum resp. maximum theoreti-
cal conductivities.
This value is important for the medium detection only and has no influence on the
determination of flow rate (see 4.7.6).
Code number to activate:
user
Example:
medium
70 %
Actual conductivity of the medium 70%