Kirby Morgan SUPERLITE 17A Checklist Download Page 3

Kirby Morgan, SuperLite, Band Mask, KMB Band Mask, EXO, SuperMask, SuperFlow, and Rex are all registered trademarks of Kirby Morgan Dive 

Systems, Inc. Use of these terms to describe products that are not manufactured by KMDSI is not permitted without written permission from KMDSI.

© Copyright 1970-2016 Kirby Morgan Dive Systems, Inc. All rights reserved. This manual is made available for the express use of owner of this Kirby 

Morgan product. No part of this manual may be reproduced, stored in any retrieval system, or transmitted, or used in any form or by any means, whether 

graphic, electronic, mechanical, photocopy, or otherwise by technology known or unknown, without the prior written permission of 

Kirby Morgan Dive Systems, Inc.

Copyright 2003-2016, Dive Lab® Inc. All rights reserved. InspTrnG 03100

STEP

PROCEDURES

INITIALS

NOTE:  On the SL-17A/B, this 

procedure will ensure the Neck 

Clamp w/Yoke Assembly is prop-

erly adjusted prior to descent.

NOTE:  All equipment must be 

adjusted properly and functioning 

correctly. The Helmet/Mask must 

be breathing easily and properly.

a. On SuperLite 17 A/B, ensure the Rear Hinge 

Tab is fully engaged on the alignment sleeve. 

Using thumb on the bottom of Regulator Body, 

and middle finger on Neck Clamp, attempt 

to “pop” Neck Clamp w/Yoke Assembly from 

bottom rim of Helmet. 
b. Diver’s Safety Harness
c. Umbilical Strain Release
d. EGS Hose Quick Disconnect
e. Boots, Gloves, Knife and other accessories.
f. Helmet supply pressure, minimum 115 psig.

8. Check Breathing

Diver:

Check to ensure helmet is breathing properly.

NOTE: All equipment must be adjusted properly 

and functioning correctly. The Helmet/Mask 

must be breathing easily and properly. 

KMDSI highly recommends that a certified KMDSI Repair Technician make all repairs and that only genuine 

KMDSI repair and replacement parts be used. Owners of KMDSI products that elect to do their own repairs 

and inspections should only do so if they possess the knowledge and experience. All inspections, maintenance, 

and repairs should be completed using the appropriate KMDSI Operations and Maintenance Manual(s). Persons 

performing repairs should retain all replacement component receipts for additional proof of maintenance history. 

Should any questions on procedures, components, or repairs arise, please contact Kirby Morgan Dive Systems, Inc., 

by telephone at (805) 928-7772 or via e-mail at [email protected], or contact Dive Lab, Inc., by telephone at 

(850) 235-2715 or via e-mail at [email protected].

NOTE: The Maintenance Log, Appendix 3, of the Operations and Maintenance Manual may be used as a template 

to create blank pages to record all the maintenance.

Technician (Print):

Signature: 

        Date:

Comments: 

3