24
© ⅯⅯⅩⅡ Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 120613002
Post Dive Procedures
4.3 Periodical Maintenance Of The Mask
All the O-rings should be replaced at least once a year.
The inlet valve on your mask should be replaced every six months or 200 operating
hours, whichever comes first.
Your entire regulator should be rebuilt every year or 400 operating hours, whichever
comes first. To perform an entire regulator rebuild (including the exhaust valve) or
to replace the face seal, special regulator mounting tools must be purchased.
KMDSI
highly recommends that Balanced EXO-26 rebuilds, face seal replacements, and
frame replacements be done by a factory trained authorized dealer.
4.4 STORAGE AND TRANSPORT OF THE MASK
KMDSI recommends that the EXO-26 Mask be stored and transported to and from
the dive site in the EXO-26 carrying bag (Part # 300-902). This bag is made from
extra heavy duty ripstop nylon and offers zippered storage in the bottom of the bag.
If the need arrises to ship your EXO-26 Mask, the original shipping box and pack-
aging should be used. However, if you do not have the original shipping box &
packaging, the box you place your mask in must be another oversized box (14" x
14" recommended) with flo-pack around it.