2
/4
www.kippzonen.com/dustiq
Needed before tare
1. Connected, working clean DustIQ with software version 2.15 or higher
2. DustIQ must be operative for minimal 3 minutes
3. Modbus registers 20-40 must be read and logged for soiling ratio’s, transmission losses, status flags,
dust slopes etc.
(see manual section 4.2)
4. A person on-site and a remote person reading DustIQ data and the manual .
5. If moving from the back of the DustIQ to the front takes more than 20 seconds, then consider adding
a third person, just to push the button.
DustIQ LED light interpretation
Regular operation, 5 seconds of blue led light with a 60 second interval
Feedback during the Tare or field calibration are given by the 2 sensors and the calibration button.
There are 2 cases:
1. Slow blinking is 1x per second, confirmation and DustIQ awaiting next input
2. Fast blinking is 10x per second, this is the error signal
for further information see error code in register 27
Both signals last 30 seconds in total, before normal operation restarts.
1
2
12 1
5
7
11
2
4
8
10
6
3
9
15 min
Time needed is 15 minutes
Die benötigte Zeit beträgt 15 min
Le temps nécessaire est de 15 min
El tiempo necesario es de 15 min
所需时间为
15
分钟
Clear, sunny day
Klarer, sonniger Tag
Journée claire et ensoleillée
Día claro y soleado
晴朗的晴天
No clouds
Keine Wolken
Pas de nuages
Sin nubes
无云
Between 2 hours before and after solar noon
Zwischen 2 Stunden vor und nach Sonnenmittag
Entre 2 heures avant et après midi solaire
Entre 2 horas antes y después del mediodía solar.
中午前后2小时之间
Clean, dry cloth
Sauberes, trockenes Tuch
Chiffon propre et sec
Paño limpio y seco
用干布擦拭清洁
Clean, demineralised water and a sponge
Sauberes, demineralisiertes Wasser und ein Schwamm
De l'eau propre et déminéralisée et une éponge
Agua limpia y desmineralizada y una esponja.
用海绵和淡水清洁
12 1
11
2
3
Example
Solar noon: 1 PM
Validate installation
No action needed
Wait
Wait 3 full minutes for the DustIQ to stabilize.
Wait
Sensors and button light up continuously for 1 minute.
Push the Calibration button on the underside of the DustIQ 3 times
in rapid succession.
No action needed
Push button 3 times
No action needed
No action needed
Check sensors or button
Slow blinking = OK and finished.
Inform person of successful completion.
Fast blinking = error.
Inform person .
Confirm successful calibration in register 27 (manual section 4.2.2.)
If unsuccessful read error code in register 27 for possible reasons and solutions.
On-Site
1
2
2
Remote office (or direct connection)
2
Sensor 1
Sensor 2
TO
P
Sensor 2
Host
Daisy chain -or-
Temperature sensor
Sensor 1
Solar panel
Calibration button
3-5 sec
Blue LED ring follows blue sensor LEDs
Calibration
During the procedure:
- Do not cast a shadow on the DustIQ
- Do not cover the sensors
1. The DustIQ is mounted properly as per instructions.
2. Power cable is connected to the DustIQ.
3. DustIQ is cleaned.
Do NOT block the sunlight on the DustIQ
TARE INSTRUCTIONS