TECHNICAL
DATA
14
Irradiance:
0 - 1400 W/m
2
(max. 4000 W/m
2
)
Non-stability:
< 0.5% sensitivity change per year
Spectral selectivity
±
2% (0,35
µ
m to 1,5
µ
m)
Construction
Receiver paint:
Carbon black
Glass domes:
Schott N-K5 optical glass 2 mm
thick, 30 mm and 50 mm outer
diameter
Desiccant: Silica
gel
Spirit level:
Sensitivity 0.1
°
(bubble half out of
the ring) Coincide with base of the
instrument.
Detector surface and base are
coplanar within 0.1
°
Materials:
Anodised aluminium case, seawater
proof quality.
Stainless steel screws corrosion free
mounted.
Anodised aluminium levelling
screws.
White plastic screen, ASA/PC
Drying
cartridge,
PMMA
Weight: 830
g
Cable length:
10 m
Dimensions:
W x H 150 x 95 mm. See figure 4