Page 1: ...ID6000 WUXI KIPOR POWER CO LTD R DIGITAL DIESEL GENERATOR SET...

Page 2: ......

Page 3: ...lure to properly follow these precautions can result in property damage serious injury or DEATH The generators are designed to give safe and dependable service if operated according to instructions Fa...

Page 4: ...RUCTIONS 2 SAFETY LABEL LOCATIONS 3 COMPONENT IDENTIFICATION 4 PRE OPERATION CHECK 5 STARTING THE ENGINE 6 GENERATOR USE 7 STOPPING THE ENGINE 8 MAINTENANCE 9 TRANSPORTING STORAGE 10 TROUBLESHOOTING 1...

Page 5: ...er hot and the cable will be burnt If the cable is long and thin the input voltage of the electric appliance will be not enough causing that the generator doesn t start In the following formula you ca...

Page 6: ...uickly and understand operation of all the controls Never permit anyone to operate the generator without proper instructions Keep children and pets away from the generator when it is in operation The...

Page 7: ...safety notes and precautions described in manual carefully 12 2 Single voltage Fuel use sticker Hook sticker Low oil pressure warning sticker Operation warning sticker Battery power warning Generator...

Page 8: ...1 Battery maintenance cover plate 2 Battery fixing belt 3 Battery Air filter sticker 12 ELECTRIC DIAGRAM 12 1 Dual voltage Boom Fuel filler Muffler exhaust pipe Maintenance door Starter motor Cover p...

Page 9: ...power Rated low speed zero load Rated high speed Rated max output power 3 Control panel 11 SPECIFICATION Rated frequency Hz Rated output kVA Max output kVA Rated voltage V Rated current A Rated rotati...

Page 10: ...put 3 1 2 Instructions of single voltage connector Function Function Function Item Item Item AC voltage input AC voltage input Current transformer input Relay control signal output 12v Current transfo...

Page 11: ...under the max speed Inverter module reaches max power This mode must be used during sudden load and unload 1 2 3 4 5 6 SV 1 SV 2 SV 3 SV 4 SV 5 SV 6 Code Parameter Key Code Item Maintenance informati...

Page 12: ...alls below the safe limit However to avoid the inconvenience of an unexpected shutdown it is still advisable to visually inspect the oil level regularly SAE20 20W 30 25 20 15 10 5 0 5 10 15 20 25 30 S...

Page 13: ...e oil should be kept in seal containers and send to the repair agency and recycling center Do not drain the oil to the ground or rubbish 2 AIR CLEANER SERVICE A dirty air cleaner will restrict air flo...

Page 14: ...or replace the element if necessary Never run the engine without the air cleaner Rapid engine wear will result from contaminants 4 Check fuel filter Check the fuel filter to be sure it is clean and in...

Page 15: ...ity may damage the generator Maintenance Schedule NOTE 1 O means normal maintenance interval 2 O 2 means generator used in dirty area Please shorten the maintenance interval 3 O 3 means maintenance a...

Page 16: ...nd fuel consumption 7 STOPPING THE ENGINE To stop the engine in an emergency turn the engine switch to the OFF position IN NORMAL USE 1 Turn the breaker to OFF 2 Switch off the connected equipment and...

Page 17: ...using the generator A Do not connect generators in parallel B Do not connect an extension to the exhaust pipe When an extension cable is required be sure to use a tough rubber sheathed flexible cable...

Page 18: ...ed Low oil level alarm lamp red Over speed alarm lamp red If red lamp is on stop the engine and find out the reason Check the load condition before they are connected to the generator Red and green la...