![KIP KIP Color 80 Operator'S Manual Download Page 65](http://html1.mh-extra.com/html/kip/kip-color-80/kip-color-80_operators-manual_1971686065.webp)
1-60
2. 9.10 User Mode 10 (Temporary clearance of E-2342)
Service call error E-2342 might be temporarily cleared by easing the error check level, which may
avoid the breakdown of KIP Color 80. Please see [Reference] on page 1-56 for the detail.
1. Press the Menu Key 10 times to select the User Mode 10.
2. Press the Enter Key. The setting value on the right hand flashes and becomes changeable.
3. Select any of “OFF”, “On1” and “On2” with pressing [ ] and [ ] keys.
OFF : Low error check level
On1 : Normal error check level
On2 : High error check level
4. Decide the setting pressing the Enter Key. The setting value stops flashing when decided.
Menu
Enter
Online
Menu
Enter
Online
Menu
Enter
Online
Menu
Enter
Online
NOTE
Select lower error check level for cancelling the service call error E-2342.