KIOUR ICE V3 Instructions Download Page 2

 

By pressing for 3 seconds the 

, manual defrost starts and ends when timer 

t2 

elapses

 

PROGRAMMING A PARAMETER 

ATTENTION

: to gain full access to the parameter’s menu, the 5th parameter 

Cod

 must be adjusted to 

22

 (see parameter table page 2). 

1. 

Press 

  to enter the parameter menu. 

2. 

Choose the parameter you want to adjust by pressing  

  or  

   and press  

  to display its value.  

3. 

Press 

  or 

  to change its value and then press 

  to store the new value. 

4. 

Press 

  to exit the parameter menu. 

 

Model 

ICE

 power supply : 230VAC 50/60Hz / Maximum power consumption: 3W.  

It is recommended using a power supply safety fuse: 0.5Α (not included) 
Evaporator and ice bucket temperature sensors NTC 10K 1% 25°C ΙΡ68 and temperature range -50÷+110°C (-58÷+230°F) (or PTC 1Κ 25oC with temperature range -50 ÷ 
+150°C (-58÷+302°F) not included) / Accuracy: ±0.5°C 
Alarm buzzer        
Compressor relay 30Α res. 250VAC normally open contact / Pump and defrost relays 10A res. 250VAC normally open contact / Max current load 16Α 
Connections: cable cross section 2.5 mm² for all relays / cable cross section from 0.25 to 1.0 mm² for the sensors 
Connections with terminal blocks 18A using cable with cable cross section up to 2.5 mm² / It is recommended using a torque wrench with maximum torque 0.4Nm                                                                                                                                                                   
Operating temperature: -15÷+55°C / Storage temperature: -20÷+80°C                                                                                                
Dimensions 37x79x81mm / The device is mounted on panel hole 29x71mm and restrained with plastic side brackets / Protection IP65 front 
Firmware: V3 
 

ELECTRICAL DIAGRAM - DIMENSIONS 

ATTENTION

: according to safety standards, the device must be properly positioned and protected from any contact with electrical parts. The device must be fastened in such 

a way that it cannot be removed without the use of tools. Disconnect the main safety switch of the installation before proceeding to any maintenance. Disconnect the power 
supply of the device before proceeding to any maintenance. Do not place the device near heat sources, equipment containing strong magnets, in areas affected by direct 
sunlight or rain. Prevent electrostatic discharges and sharp objects from been inserted to the device. Separate signal cables from power supply cables to prevent electromagnetic 
disorders. Signal cables must never be in the same pipe with the power supply cables. 

ATTENTION

: Read carefully the technical specifications and make sure that the working 

conditions are appropriate. According to safety standards, the device must be fastened in such a way that it cannot be removed without the use of tools.  
 

Dimensions are in mm. The device is mounted on panel hole with cut 29x71mm and restrained with plastic side brackets. 
                  
  
 

 

 
 
 
 
 
 
 

PARAMETER TABLE 
No 

 

description 

min 

max 

ICE 

UOM 

SΡ2 

ice bucket SET POINT: temperature control of the ice bucket 

-50 

+150 

°C/°F 

SLo 

minimum temperature limit of SPo 

-50 

SΗi 

-20 

°C/°F 

SHi 

maximum temperature limit of SPo 

SLo 

+150 

°C/°F 

dF2 

differential of temperature sensor ice bucket SP2 

+150 

°C/°F 

Cod 

code to enter parameter’s menu Cod = 22 

255 

Cr 

minimum pause time of the compressor 

minutes 

dE5 

defrost’s end temperature: in case of evaporator’s sensor malfunction (

LF1

), defrost does not end based on 

the dE5 parameter but when timer 

t2

 elapses. 

70 

20 

°C/°F 

dt

 

(not used) 

SPo 

Evaporator SET POINT: temperature control of the evaporator 

SLo 

SΗi 

-12 

°C/°F 

10 

do 

Derfrost Mode: electrical for do = 0 or hot-gas for do = 1 (the compressor relay works in parallel with the 
defrost relay during the defrosting process) 

0

 

1

 

0=electrical

 

-

 

11 

dr

 

(not used) 

12 

SEN 

Type of sensor NTC/PTC.  0 = PTC / 1 = NTC 

0 = PTC 

13 

SE1 

zero adjustment of evaporator temperature sensor 

-9

 

+15

 

0

 

°C/°F

 

14 

SE2 

zero adjustment of ice bucket temperature sensor 

-9

 

+15

 

0

 

°C/°F

 

15 

tS

 

(not used)

 

-

 

-

 

-

 

-

 

16 

FC 

Switch between °C/°F (0=°C, 1=°F) ATTENTION: toggling between °C/°F does not change SPo 

0=°C 

°C/°F 

17 

t1 

 

countdown timer where the compressor relay remains activated as long as the evaporator reaches the 
desired set temperature 

1

 

255

 

10

 

minutes

 

18 

t2 

countdown timre where the defrost relay remains ON 

1

 

255

 

2

 

minutes

 

19 

dHL

 

delay time until the activation of the alarm “AHi” and “ALo” 

99 

minutes 

20 

t3 

maximum compressor operating time during the cooling process until it reaches the desired set point. At the 
end of time t3, all functions and thermostat relays are deactivated and "

FFF

" indication is displayed. The 

alarm is deactivated automatically by restarting the device 

0

 

255

 

30

 

minutes

 

21 

ΑLo

 

low evaporator temperature alarm 

-50 

+150 

-30 

°C/°F 

22 

ΑHi

 

high evaporator temperature alarm 

-50 

+150 

+35 

°C/°F 

MANUAL DEFROST  

TECHNICAL SPECIFICATIONS 