background image

 

 
 
 
 
 
 
 
 
 
 
 
 
      1.                                              2. 
 
 
 
 
 
 
 
 
       3.                                              4. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

1) Open the two hinged reflector panels. 2 & 3) Insert the 
lamp base into the lamp connector. 4) Insert the lamp tip into 
the lamp clip. Close the reflector panels. 

 

Align the pins of the Gel 
Frame with the 

inner

 

(closest to lamps) holes of 
the Accessory Holder.  
Pull back the pins and 
release into the holes to 
secure the gel frame. 

Summary of Contents for VistaBeam 300

Page 1: ...Operation Manual VistaBeam 600 300 Part No 3100041 Rev C 01 07 2008 ...

Page 2: ...nt 230VAC VIS 3C 120 VistaBeam 300 Center Mount 120VAC VIS 3C 230 VistaBeam 300 Center Mount 230VAC LVR V690 VistaBeam 600 Louver Honeycomb 90 Included LVR V390 VistaBeam 300 Louver Honeycomb 90 Included GFR V6 VistaBeam 600 Gel Frame Included GFR V3 VistaBeam 300 Gel Frame Included ...

Page 3: ...ouver Honeycomb 90 Included GFR V6 VistaBeam 600 Gel Frame Included GFR V3 VistaBeam 300 Gel Frame Included VIS 6Y 120 VistaBeam 600 Yoke Mount 120VAC VIS 6Y 230 VistaBeam 600 Yoke Mount 230VAC VIS 3Y 120 VistaBeam 300 Yoke Mount 120VAC VIS 3Y 230 VistaBeam 300 Yoke Mount 230VAC ...

Page 4: ...Louver 90 1 Ship Case Dimensions 41 5 x 15 5 x 44 105 5 x 39 5 x 112cm Weight 140lb 63kg KIT V6C 120 2 VistaBeam 600 Center Mount Kit 120VAC 2 Unit KIT V6C 230 2 VistaBeam 600 Center Mount Kit 230VAC 2 Unit Kit Contents 2 VistaBeam 600 w Center Mount 2 VistaBeam Louver 90 1 Ship Case Dimensions 41 x 27 x 44 102 5 x 67 5 x 112cm Weight 205lb 93kg ...

Page 5: ...VistaBeam 300 Center Kit 120VAC KIT V3C 230 VistaBeam 300 Center Kit 230VAC Kit Contents 1 VistaBeam 300 w Center Mount 1 VistaBeam Louver 90 1 Ship Case Dimensions 42 x 14 5 x 25 5 107 x 37 x 65cm Weight 82 3lb 37kg ...

Page 6: ...lamp base into the lamp connector 4 Insert the lamp tip into the lamp clip Close the reflector panels Align the pins of the Gel Frame with the inner closest to lamps holes of the Accessory Holder Pull back the pins and release into the holes to secure the gel frame ...

Page 7: ...tape directly to the gel frame The clips are not necessary when taping the gel Align the pins of the louver with the outer farthest from lamps receptacle holes on the Accessory Holder Pull back the pins and release into the hole to secure the louver The large holes on the Accessory Holder can be used as rigging points for example a 4 point rope hang ...

Page 8: ...ombo stand or hung from a pipe hanger Rotation and Tilt Controls A The gold lock lever controls the rotation of the fixture B The black knob controls the tilt Accessory part MTP V63H1 can be used to mount the VistaBeam from a Junior Pipe Hanger The Hanging Adapter is held in place by a safety screw and a setscrew A Lock Knob adjusts rotation of the arm ...

Page 9: ...llen Head screws The VistaBeam 600 Yoke YOK V6 can mount the fixture in either a horizontal and vertical lamp orientation The VistaBeam 300 Yoke YOK V3 mounts the fixture in a horizontal lamp orientation only The Mount fittings are U S industry standard Speed Rail 1 fittings They accept a 1 5 8 outside diameter pipe These fittings enable custom frames to be constructed for special rigging applicat...

Page 10: ...ignals from Dimmer Board DMX OUT relays DMX signal through to other Fixtures or Instruments B C G H A F I E D A Junior Pin 28mm Assembly MTP I80 sold separately is necessary for mounting the yoke to a Junior Combo stand or a Junior Pipe hanger ...

Page 11: ...ghts up Amber when valid DMX signal is present IMPORTANT The dimmer board light console should have its channel set to LINEAR light output response LINEAR response is the default setting on most dimmer boards POWER Provide 120 VAC or 230 VAC depending on model Do not dim the fixture through a dimming circuit If powering the fixtures through a dimmer board set the dimmer profile to non dim FUSE Pro...

Page 12: ...the outside tubes will turn off first Note Manual lamp switching is disabled as soon as DMX cables are applied VistaBeam 300 Switching STD operates lamps in Standard Output Mode HO operates lamps in High Output Mode Lamps can be controlled manually through a hand held Dimmer DIM 5 For Manual Remote Lamp Control plug in the accessory DIM 5 controller Rotating the dimmer knob turns lamps on and off ...

Page 13: ...alled a Reflected Wave and may create transmission errors by causing valid DMX signals to be canceled After the DMX address is entered the VistaBeam 600 Fixture automatically assigns 7 addresses to lamp positions 1 6 and address 7 controls the STD HO setting Note Manual lamp switching is disabled as soon as the DMX cables are applied For Manual control with DMX cables plugged in set address to 000...

Page 14: ...mer Board and jumper the Fixtures in a series DMX pin out wiring follows the USITT DMX512 standard Pin 1 Shield Pin 2 Data Pin 3 Data Pin 4 Spare Pin 5 Spare Note Pin four and five in the Fixture are connected internally as Pin four to four and Pin five to five Connecting Pin four and five as the pass thru allows secondary data to be passed through for other equipment Setting the unit to FIX mode ...

Page 15: ...automatically assigns address 007 as the control address for the STD HO setting Not assigning the 7th address results in the fixture operating at the HO setting For the sake of simplification it is advisable to select address sequences such as 10 20 30 40 and so on This also allows the operator to change from Fixture Mode to Individual Lamp Mode without readdressing the fixtures Never assign the 7...

Page 16: ...ons 1 6 and the 7th address controls the STD HO settings For the sake of simplification it is advisable to select address sequences in groups of 10 for VistaBeam 600 VistaBeam 300 such as 10 20 30 40 and so on VistaBeam 300 Lamp Sequence The VistaBeam 600 s 7th DMX address controls the STD HO function The VistaBeam 300 s 4th DMX address controls the STD HO function Programming the STD HO address a...

Page 17: ...Lamp 6 6 STD HO 7 VistaBeam 300 Address Sequence DMX Address 001 Lamp DMX Address Lamp 1 1 Lamp 2 2 Lamp 3 3 STD HO 4 VistaBeam 600 Lamp Sequence VistaBeam 300 Lamp Sequence For example if the VistaBeam base address is set at 001 the configurations below will provide lamps individually addressable through DMX512 ...

Page 18: ... 45 LVR V360 VistaBeam 300 Louver 60 LVR V390 VistaBeam 300 Louver 90 LVR V645 VistaBeam 600 Louver 45 LVR V660 VistaBeam 600 Louver 60 LVR V690 VistaBeam 600 Louver 90 MTP V63C VistaBeam 63 Center Mount Assembly GFR V6 VistaBeam 600 Gel Frame GFR V3 VistaBeam 300 Gel Frame ...

Page 19: ... 28mm XLR 515 DMX Cable 5 Pin xlr 15ft XLR 525 DMX Cable 5 Pin xlr 25ft YOK V6 VistaBeam 600 Yoke Assembly YOK V3 VistaBeam 300 Yoke Assembly MTP I80 VistaBeam Image Junior Pin Assembly 28mm To use with Yoke MTP V63JR VistaBeam 63 Junior Adapter 28mm ...

Page 20: ...aBeam 600 Center 41 x 27 x 44 122 lb VistaBeam 600 2 Ship Case 2 102 5 x 67 5 x 112cm 55 kg Louver 4 KAS V31 VistaBeam 300 Center 42 x 14 5 x 25 5 55 lb VistaBeam 300 1 Ship Case 107 x 37 x 65cm 24 8 kg Louver 2 KAS VL8 VistaBeam 8 Lamp 38 x 14 x 7 13 4 lb VistaBeam Lamps Ship Case 96 5 x 35 6 x 17 8cm 6 kg 8 KAS VL8 C VistaBeam 8 Lamp 37 x 7 5 x 14 13lb VistaBeam Lamps Travel Case 94 x 19 1 x 35 ...

Page 21: ...elect Phono jack input for Remote Control Switching 1 6 Lamp type 96W CFL VistaBeam 600 Center Mount VistaBeam 600 Yoke Mount Power Requirements 120VAC or 230VAC Amperage 9 1 amps at 120VAC 4 6 amps at 230VAC Weight w lamps 47 5lb 21 4kg Dimensions 41 5 x 39 5 x 8 5 105 5 x 100 5 x 21 5cm Remote Lamp Select Phono jack input for Remote Control Switching 1 6 Lamp type 96W CFL ...

Page 22: ...AC or 230VAC Amperage 4 8 amps at 120VAC 2 4 amps at 230VAC Weight w lamps 28 6lb 12 9kg Dimensions 37 5 x 20 x 8 5 95 5 x 51 x 21 5cm Remote Lamp Select Phono jack input for Remote Control Switching 1 3 Lamp type 96W CFL Power Requirements 120VAC or 230VAC Amperage 4 8 amps at 120VAC 2 4 amps at 230VAC Weight w lamps 28 2lb 12 7kg Dimensions 41 5 x 23 5 x 8 5 105 5 x 59 5 x 21 5cm Remote Lamp Sel...

Reviews: