11
B) Individual Lamp / Fixture Switch:
Converts between INDIVIDUAL LAMP
and FIXTURE methods of DMX control.
C) DMX
Address
: Sets DMX Address of Fixture.
D) STD/HO Switch: STD
operates lamp in standard output mode.
HO
operates
Lamps in High Output mode.
E) REMOTE Input Jack:
Input for
DIM-5
remote controller
F) Power
Switch:
Has a built-in indicator light, which can detect if AC power is
present in power cord.
"O" = OFF position
G) Manual SELECT Dial:
Turns lamps on and off manually without connecting
DMX Cable to Fixture.
H) END of LINE Switch:
Terminates DMX signal at the end of Fixture series.
I)
DMX Indicator Light:
Lights up Amber when valid DMX signal is present.
IMPORTANT!
The dimmer board/light console should have its channel set to LINEAR light output
response. (LINEAR response is the default setting on most dimmer boards.)
POWER
Provide 120 VAC or 230 VAC depending
on model.
Do not dim the fixture through a dimming
circuit.
If powering the fixtures through a dimmer
board, set the dimmer profile to non-dim.
FUSE
Provides circuit protection.
Note: If Fuse
is "blown" or "open" replace with same
type of fuse rating as marked.
Load Considerations:
The Kino Flo ballasts used in the VistaBeam are not power factor corrected.
They will draw double the current on the neutral from what is being drawn
on the two hot legs. On large installations it may be necessary to double
your neutral run so as not to exceed your cable capacity.