Kino Flo ParaZip 200 Operation Manual Download Page 6

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

    
 
 
 

 
 
 
 
 
 
 
     
 
 
 
 
 
 
 
 
 
 
 

    

The on-board dimmer dial can manually dim lamps. 
 

The REMOTE DIM

 jack enables the use of a 

handheld remote control dimmer (Part # 

DIM-5

,  

Hand Held Dimmer). 
 

The

MANUAL DIM LAMPS 

switch selects 4 or 2 lamp 

operation. In the 

4

 setting all four lamps are dimmed. 

In the 

2

 setting the center two lamps are dimmed.  

 

Note: 

All manual controls are disabled as soon as the DMX cable 

is applied. For Manual control with DMX cables plugged in,  
set address to”000”. There is a 5 second delay when switching 
between DMX and Manual control.

 

DMX Addressing 

Prior to hanging any instruments,  
set the DMX address of each Fixture. 

 
Push the tabs above or below the number 
window to set the address. (Valid addresses 
range from 001 to 512.) The light above the 
address block will illuminate if a DMX signal  
is present.  

The 

DMX DIM CHANNELS

 feature allows user to 

select two sets of lamps for DMX dimming control. 
The 

ParaZip 400 Select

 operates on one or two 

DMX addresses. 
 

Position 1 

requires one DMX address and

 

renders 

control of all four lamps on one dimmer channel. 
 

Position

 

2

 requires two DMX addresses to control 

4 lamps on two addresses and two dimmer 
channels.  
 
The 1

st

 address controls the 

inner two

 lamps. 

The 2

nd

 address controls the 

outer two

 lamps. 

Summary of Contents for ParaZip 200

Page 1: ...Operation Manual ParaZip 200 400 Part No 3100039 Rev B 01 07 2008 ...

Page 2: ...AC ZIP 400 230 ParaZip 400 DMX 230VAC GFR Z4 ParaZip 400 Gel Frame GFR Z2 ParaZip 200 Gel Frame LVR Z4 S ParaZip 400 Louver Silver LVR Z2 S ParaZip 200 Louver Silver ZIP 200 120 ParaZip 200 DMX 120VAC ZIP 200 230 ParaZip 200 DMX 230VAC ...

Page 3: ...lace Lamp Base Cover and push down on pins to lock To release lamps press Red Button and lift lamp base out The Gel Frame is secured to the fixture by 4 spring loaded pins Align the pins of the Gel Frame with the oval receptacle holes on the edge of the fixture Pull back the pins and release into the receptacles to properly secure the Gel Frame ...

Page 4: ...long edge of the Louver into the lower channel containing a set of leaf springs Press down on the Louver and slip the upper edge of the louver into the upper channel of the fixture Honeycomb louvers have tabs on the side to enable easy handling To remove reverse the procedure Attach the Barndoors sold separately to the two receptacles located along the top and bottom edge of the fixture Adjust the...

Page 5: ...then restrike If temperatures are too low try to warm up the fixture to at least 60 F Lamps will turn on at preset dimmer settings as long as the temperature is above 60 F or 15 C DMX In DMX Out DMX in receives DMX signals from Dimmer Board DMX Out relays DMX signal through to other fixtures or Instruments End of Line Terminates DMX signal at the end of Fixture series Manual Dimmer Control Power S...

Page 6: ...trol DMX Addressing Prior to hanging any instruments set the DMX address of each Fixture Push the tabs above or below the number window to set the address Valid addresses range from 001 to 512 The light above the address block will illuminate if a DMX signal is present The DMX DIM CHANNELS feature allows user to select two sets of lamps for DMX dimming control The ParaZip 400 Select operates on on...

Page 7: ... to END OF LINE when the Fixture is the last DMX control device in the chain Note When the last Fixture s DMX Term is set to END OF LINE it will absorb all energy in the DMX line ensuring DMX signals are transmitted correctly If a signal is not terminated it is called a Reflected Wave and may create transmission errors by causing valid DMX signals to be canceled The ParaZip 200 operates on one add...

Page 8: ...ow light is off there is no DMX signal Establish a valid DMX signal With DMX cable plugged in and yellow indicator on 1 Address must be between 001 and 512 Addresses above 512 are invalid 2 The dimmer setting on lighting board must in the full up mode 3 The last fixture must have the DMX termination switch set to END of LINE Numerous terminated fixtures on a DMX run will result in DMX signal corru...

Page 9: ...Hand Held remote dimmer with 15ft dimming cable MTP I40 Baby Receiver Mount MTP I80 Junior Pin Mount LVR Z445 ParaZip 400 Louver 45 LVR Z460 ParaZip 400 Louver 60 LVR Z490 ParaZip 400 Louver 90 LVR Z245 ParaZip 400 Louver 45 LVR Z260 ParaZip 400 Louver 60 LVR Z290 ParaZip 400 Louver 90 ...

Page 10: ...10 KAS Z41 ParaZip 400 Case KAS Z21 ParaZip 200 Case XLR 525 Dmx Cable 5 Pin xlr 25ft XLR 515 Dmx Cable 5 Pin xlr 15ft KAS CL6 6 Lamp Carry Case 55W Compact ...

Page 11: ...es 55 watt compact fluorescent lamps with 2G11 base Switching 4 lamp and 2 lamp on off Dimming Manual and DMX ZIP 200 ParaZip 200 Power requirements 120VAC or 230VAC Amperage 1 1 amps at 120VAC 6 amps at 230VAC Weight with lamps louver and gel frame 13 9lbs 6 3kg Dimensions 50 x 11 x 5 127 x 28 x 12 5cm Lamp types 55 watt compact fluorescent lamps with 2G11 base Switching 2 lamps on off Dimming Ma...

Page 12: ...tronic Equipment This symbol on the product or on its packaging indicates that this product shall not be treated as household waste This product is made of recyclable materials and should be disposed of in accordance with local and state regulations ...

Reviews: