![Kino Flo ParaZip 200 Operation Manual Download Page 6](http://html.mh-extra.com/html/kino-flo/parazip-200/parazip-200_operation-manual_1971377006.webp)
6
The on-board dimmer dial can manually dim lamps.
The REMOTE DIM
jack enables the use of a
handheld remote control dimmer (Part #
DIM-5
,
Hand Held Dimmer).
The
MANUAL DIM LAMPS
switch selects 4 or 2 lamp
operation. In the
4
setting all four lamps are dimmed.
In the
2
setting the center two lamps are dimmed.
Note:
All manual controls are disabled as soon as the DMX cable
is applied. For Manual control with DMX cables plugged in,
set address to”000”. There is a 5 second delay when switching
between DMX and Manual control.
DMX Addressing
Prior to hanging any instruments,
set the DMX address of each Fixture.
Push the tabs above or below the number
window to set the address. (Valid addresses
range from 001 to 512.) The light above the
address block will illuminate if a DMX signal
is present.
The
DMX DIM CHANNELS
feature allows user to
select two sets of lamps for DMX dimming control.
The
ParaZip 400 Select
operates on one or two
DMX addresses.
Position 1
requires one DMX address and
renders
control of all four lamps on one dimmer channel.
Position
2
requires two DMX addresses to control
4 lamps on two addresses and two dimmer
channels.
The 1
st
address controls the
inner two
lamps.
The 2
nd
address controls the
outer two
lamps.