![Kino Flo ParaZip 200 Operation Manual Download Page 5](http://html.mh-extra.com/html/kino-flo/parazip-200/parazip-200_operation-manual_1971377005.webp)
5
Warning! To Ensure Proper Operation
ALWAYS TURN
OFF
THE FIXTURE BEFORE connecting or
disconnecting lamps. After the lamps are properly installed, the Ballast
can be turned on. Avoid operating in temperatures above 125
°
F (51
°
C) or
below 60
°
F (15
°
C).
In temperatures below 60
°
F or 15
°
C the ballast may take longer to strike.
If lamps do not strike within 5 seconds, switch the ballast to OFF, and try
again. Check that the lamps are properly seated and the dimmer is up full,
then restrike. If temperatures are too low, try to warm up the fixture to
at least 60
°
F. Lamps will turn on at preset dimmer settings as long as the
temperature is above 60
°
F or 15
°
C.
DMX-In & DMX-
Out:
DMX-in receives
DMX signals from
Dimmer Board,
DMX-Out relays
DMX signal
through to other
fixtures or
Instruments.
End of Line:
Terminates DMX
signal at the end of
Fixture series.
Manual
Dimmer
Control
Power Switch:
Turns fixture on
and off.
DMX / MANUAL
Lamp Select:
Sets the fixture for
2 or 4 lamp
operation.
DMX
Address:
Sets DMX
address of
Fixture.
DMX Indicator:
Lights if valid
DMX signal is
present.
Remote Dimmer
Jack:
Hand held
dimmer control
input jack.
Fuse:
Time
delay
fuse.